On-line determination of ammonia at low pptv mixing ratios in the CLOUD chamber

نویسندگان

  • F. Bianchi
  • J. Dommen
  • S. Mathot
  • U. Baltensperger
چکیده

A new instrument for the on-line determination of ammonia was developed. Since ammonia is a rather sticky compound, sampling losses were minimised with a new sampling device where the ammonia was transferred to the liquid phase only 5 mm after the inlet tip. The liquid phase was then analyzed by long pathlength absorption spectrophotometry using the Berthelot reaction with phenol and hypochlorite as reagents. The measurements were made during the CLOUD3 campaign at CERN where the influence of ammonia on the nucleation rate was studied. At stable conditions the detection limit reached with this instrument was 35 pptv (air flow rate of 2 l min−1, liquid flow rate of 0.3 ml min−1), although occasionally the instrument was affected by background problems. The range of mixing ratios during this campaign was varied from the background contamination (< 35 pptv) up to around 2 ppbv. The measured ammonia concentration was correlated with the rate of ammonia injected into the chamber, but with a response time of several hours due to the high tendency of ammonia to adsorb to or to desorb from surfaces. Since it was found that ammonia strongly increases the nucleation rate already at the lowest measured concentration, future work will focus on further decreasing the detection limit of the instrument.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Chemical Ionization Mass Spectrometer for Ambient Measurements of Ammonia

This study presents a chemical ionization mass spectrometer (CIMS) for fast response, in-situ measurements of gas phase ammonia (NH3). The NH3 background level detected with the CIMS ranged between 0.3–1 ppbv, with an uncertainty of 30 pptv under optimized conditions. The instrument sensitivity varied from 4–25 Hz/pptv for >1 MHz of reagent ion signals (protonated ethanol ions), with a 30% unce...

متن کامل

A chemical ionization mass spectrometry technique for airborne measurements of ammonia

[1] A chemical ionization mass spectrometer (CIMS) utilizing protonated acetone dimer ion chemistry to measure gas-phase ammonia (NH3) from the NOAA WP-3D aircraft is described. The average sensitivity determined from in-flight standard addition calibrations ranged from 2.6 to 5 ion counts s 1 pptv , depending on flow conditions, for 1 MHz of reagent ion signal. The instrument time response was...

متن کامل

Ambient pressure proton transfer mass spectrometry: detection of amines and ammonia.

An instrument to detect gaseous amines and ammonia is described, and representative data from an urban site and a laboratory setting are presented. The instrument, an Ambient pressure Proton transfer Mass Spectrometer (AmPMS), consists of a chemical ionization and drift region at atmospheric pressure coupled to a standard quadrupole mass spectrometer. Calibrations show that AmPMS sensitivity is...

متن کامل

Seasonal variation of peroxyacetylnitrate (PAN) in coastal Antarctica measured with a new instrument for the detection of sub-part per trillion mixing ratios of PAN

An automated gas chromatograph with sample pre-concentration for the measurement of peroxyacetylnitrate (PAN) was constructed with a minimum detection limit below 1 pptv. This instrument was deployed at the British Antarctic Survey’s Halley Research Station, Antarctica (75.6 S, 26.6 W) as part of the CHABLIS (Chemistry of the Antarctic Boundary Layer and the Interface with Snow) campaign. Hourl...

متن کامل

Mixing of the Immiscible Liquids in the Entrance Region of a T-Type Chamber Using Laser Induced Fluorescence (LIF) Method

A Laser Induced Fluorescence technique (LIF) has been used to study the mixing behavior of two emerging streams in a T-Type mixing chamber. A mixing index on the basis of digital image light intensities is calculated. It has been shown that averaging over more than 800 images leads to a stable mixing index calculation. Moreover, the effect of equal and un-equal flow rates on the mixing behavior...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012