SU-E-T-691: Comparison of 5-Channel Versus Single and 9-Channel Vaginal Cylinder Treatment Plans.
نویسندگان
چکیده
PURPOSE To compare the quality of 5-channel vaginal cylinder treatment plans for endometrial cancer to single channel and 9-channel plans. Using more channels tends to spare the rectum and bladder, while creating hot spots and longer planning and treatment times. The objective is to determine if the 5-channel plans offer a beneficial compromise to the single and 9-channel plans. METHODS Fifteen treatment plans from 3 patients were evaluated using the Oncentra MasterPlan (Nucletron inc.) treatment planning system. Each of the 15 plans was previously treated with 9 channels from a 35mm diameter multi-channel cylinder, using Oncentra's IPSA inverse planning tool. The prescribed dose was 500cGy × 5 fractions to the 5mm vaginal cuff rind. A 5-channel plan was created by removing the 2 channels closest to the bladder and the 2 closest to the rectum from the 9-channel plan, then proportionately adjusting the weights in inverse planning for the bladder, rectum, and D150, while keeping D95 within 0.1% (D95 is typically around 95%). The single channel plan was normalized to a 5mm distance from the cylinder wall. RESULTS When compared to single channel, the 5-channel plans had an average of 3.5% and 6.7% lower doses to the bladder and rectum, respectively. The V200 was lower in 7/15 plans (-0.2% average), and V150 was higher than single channel on 13/15 plans (+5.7% average). When compared to 9-channel, the 5-channel plans had lower dose to the bladder on 9/15 plans (-0.3% average), and a lower V150 on 9/15 plans (-0.6% average). The 5-channel rectum dose was higher on all plans (+4.4% average), and the V200 was higher on 8/15 plans (0.3% average). CONCLUSION The 5-channel vaginal cylinder plans offer a reasonable compromise between single channel and 9-channel plans.
منابع مشابه
Modified Fletcher's 3-channel brachytherapy system with vaginal line source loading versus uterine tandem and vaginal cylinder system in Stage IIIA cervical cancer
PURPOSE The uterine tandem with open-ended vaginal cylinder is the most commonly used brachytherapy system for Federation Internationale de Gynecologie et d'Obstetrique (FIGO) Stage IIIA cervix cancer at the National Cancer Centre, Singapore. Without the 3-channel ovoid system, the dose to the parametrium is often compromised. In this study, a vaginal cylinder that could potentially be incorpor...
متن کاملDosimetric comparison of interstitial brachytherapy with multi-channel vaginal cylinder plans in patients with vaginal tumors
BACKGROUND To evaluate the dosimetric performance of multi-channel vaginal cylinder (MCVC) against interstitial brachytherapy (ISBT) for the treatment of vaginal tumors. METHODS Vaginal tumors with extension of > 0.5 cm and ≤ 2 cm from the lateral vaginal wall and/or ≤ 1 cm in height above the vaginal vault were retrospectively selected from a ISBT registry trial database. The selected patien...
متن کاملSingle versus multichannel applicator in high-dose-rate vaginal brachytherapy optimized by inverse treatment planning
PURPOSE To retrospectively compare the potential dosimetric advantages of a multichannel vaginal applicator vs. a single channel one in intracavitary vaginal high-dose-rate (HDR) brachytherapy after hysterectomy, and evaluate the dosimetric advantage of fractional re-planning. MATERIAL AND METHODS We randomly selected 12 patients with endometrial carcinoma, who received adjuvant vaginal cuff ...
متن کاملUse of a Flexible Inflatable Multi-Channel Applicator for Vaginal Brachytherapy in the Management of Gynecologic Cancer
INTRODUCTION Evaluate use of novel multi-channel applicator (MC) Capri™ to improve vaginal disease coverage achievable by single-channel applicator (SC) and comparable to Syed plan simulation. MATERIALS AND METHODS Twenty-eight plans were evaluated from four patients with primary or recurrent gynecologic cancer in the vagina. Each received whole pelvis radiation, followed by three weekly trea...
متن کاملSU-D-213AB-02: Optimal Design of Multichannel Vaginal Cylinder Applicators for High Dose Rate Brachytherapy.
PURPOSE To determine the optimal location of catheters in multichannel vaginal applicators to appropriately cover the vaginal cuff target and minimize dose to the organs at risk (OARs) and hot spots in the target. METHODS A new multichannel vaginal applicator with a diameter of 30 mmconsists of a single central catheter and an outer array of eight catheters. A total of 20 plans were generated...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 40 6Part21 شماره
صفحات -
تاریخ انتشار 2013