Quantitative Study of Porosity and Pore Features in Moldavites by Means of X-ray Micro-CT
نویسندگان
چکیده
X-ray micro-computer aided tomography (μ-CT), together with optical microscopy and imaging, have been applied to the study of six moldavite samples. These techniques enabled a complete characterization to be made of the textural features of both Muong Nong-type and common splashform moldavites. A detailed study of the size and distribution of pores or bubbles confirmed the marked variability in pore size among the samples, as well as within each sample, and indicated in the Muong Nong-type moldavites the presence of at least two deformation stages which occurred before and after pore formation.
منابع مشابه
Empirical correlation for porosity deduction from X-ray computed tomography (CT)
For obtaining reservoir petrophysical properties, for example porosity, non-destructive methods such as X-ray computed tomography, CT, seems to be precise and accurate. Porosity is deducted from the CT image with a single scan via different techniques, such as pore space detection by image segmentation techniques then correlation with porosity. More than one hundred samples with carbonate li...
متن کامل3D Microtomographic Characterization of Precision Extruded Poly- -caprolactone Scaffolds
One of the dominant approaches to tissue engineering is the seeding of biodegradable, biocompatible polymer scaffolds with progenitor cells prior to 3D culture or implantation. The microarchitecture of these scaffolds has direct effects upon the ability of cells to attach, migrate, and differentiate. Microtomographic (micro-CT) scanners enable high-speed 3D characterization of the salient featu...
متن کاملThree-dimensional Quantitative Porosity Characterization of Syringe- versus Hand-mixed Set Epoxy Resin Root Canal Sealer.
The aim of the present study was to compare the porosity characteristics of AH Plus Jet(tm) syringe-mix and the conventional hand-mixed AH Plus root canal sealers by three-dimensional quantitative high-resolution micro-computed tomography (micro-CT). Seven test specimens were prepared from each tested sealer by a single operator following the manufacturer's instructions and poured into pre-lubr...
متن کاملMineral precipitation-induced porosity reduction and its effect on transport parameters in diffusion-controlled porous media
BACKGROUND In geochemically perturbed systems where porewater and mineral assemblages are unequilibrated the processes of mineral precipitation and dissolution may change important transport properties such as porosity and pore diffusion coefficients. These reactions might alter the sealing capabilities of the rock by complete pore-scale precipitation (cementation) of the system or by opening n...
متن کاملComparison of different nano- and micro-focus X-ray computed tomography set-ups for the visualization of the soil microstructure and soil organic matter
This study explores the potential of different X-ray computed tomography (X-ray CT) set-ups for the discrimination of soil mineral matter, soil organic matter (OM) and the pore phase. Different X-ray sources, detectors and filtering methods were investigated. Use of a low-energy detector as well as a Cu-filter decreased the potential for phase segmentation in X-ray CT images of an artificial sa...
متن کامل