Reliability of different body temperature measurement sites during aortic surgery.

نویسندگان

  • L Göbölös
  • A Philipp
  • P Ugocsai
  • M Foltan
  • A Thrum
  • S Miskolczi
  • D Pousios
  • S Khawaja
  • M Budra
  • S K Ohri
چکیده

OBJECTIVE We retrospectively performed a comparative analysis of temperature measurement sites during surgical repair of the thoracic aorta. METHODS Between January 2004 and May 2006, 22 patients (mean age: 63 ± 12 years) underwent operations on the thoracic aorta with arterial cannulation of the aortic arch concavity and selective antegrade cerebral perfusion (ACP) during deep hypothermic circulatory arrest (HCA). Indications for surgical intervention were acute type A dissection in 14 (64%) patients, degenerative aneurysm in 6 (27%), aortic infiltration of thymic carcinoma in 1 (4.5%) and intra-aortic stent refixation in 1 (4.5%). Rectal, tympanic and bladder temperatures were evaluated to identify the best reference to arterial blood temperature during HCA and ACP. RESULTS There were no operative deaths and the 30-day mortality rate was 13% (three patients). Permanent neurological deficits were not observed and transient changes occurred in two patients (9%). During re-warming, there was strong correlation between tympanic and arterial blood temperatures (r = 0.9541, p<0.001), in contrast to the rectal and bladder temperature (r = 0.7654, p = n.s; r = 0.7939, p = n.s., respectively). CONCLUSION We conclude that tympanic temperature measurements correlate with arterial blood temperature monitoring during aortic surgery with HCA and ACP and, therefore, should replace bladder and rectal measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thermoregulatory Mechanisms of Jersey Adult Cattle and Calves Based on Different Body Sites Temperature

In this experiment six healthy adult dairy Jersey cattles and eight calves (aged 4-6 months) were selected to measure temperature of different body skin sites, rectal temperature, respiration and heart rates during summer and winter. Body sites maximum and minimum temperature in calves during summer belonged to the ear, forehead, right flank, abdomen (38.4-38.9 ˚C) and carpus (32 ˚C). This was ...

متن کامل

بررسی مقایسه‌ای میزان درجه حرارت مری، گوش و مقعد در کودکان تحت جراحی قلب باز

Introduction: cardiac surgery by cardiopulmonary bypass (CPB) is performed accompanying with hypothermia. Measuring the body temperature during hypothermia is very important. The aim of this study was to compare esophageal, tympanic and rectal temperatures in pediatric patients below 12 years old undergoing open heart surgery. Methods: This study was a cross-sectional descriptive and analytic ...

متن کامل

Management of anesthesia in a patient with ruptured abdominal aortic aneurysm: A case report

Introduction: Abdominal aortic aneurysm is a multifactorial condition which associated with aging and atherosclerosis. During aneurysm surgery, hypotension after aortic clamp removing occure commonly that require specific treatments. This case report showes administration of blood and hemodynamic control methods after aortic unclumping during aortic aneurysm surgery. Patient: A 75&ndash;years-o...

متن کامل

Reliability of Visually Estimated Blood Loss with Hemoglobin Measurement: 200 Cases of Craniosynostosis Surgery

Background Bleeding is one of the most common complications of craniosynostosis surgery, which its appropriate management is associated with better post-operative outcomes. The aim of this retrospective study was to evaluate the visual estimated blood loss in intraoperative management of infants with craniosynostosis surgery. Materials and Methods This retrospective study was performed on 200 p...

متن کامل

A Rare Case of Severe Aortic Regurgitation with Silent Ascending Aortic Dissection

Classically, ascending aortic dissection (AD) presents as sudden, severe chest pain that is tearing type and radiates to the back. Herein, we present a rare case of severe aortic regurgitation with silent ascending AD, which had no chest pain symptoms. The aortic valve apparatus probably masked this AD; therefore, it was not detected by echocardiography and during the surgery.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Perfusion

دوره 29 1  شماره 

صفحات  -

تاریخ انتشار 2014