Iodine contamination of urine samples by test strips.
نویسندگان
چکیده
2406 41 5 1 73 lodate has been recently introduced in the patches of 1395 47.6 3:41 Combur-8 Test, which involves a peroxidase (EC 1.11.1.7) 982 24.2 2.46 redox indicator system (glucose, hemoglobin) to decrease the interference ofthe reaction with ascorbic acid (4); potassium iodide is incorporated as chromogen in the glucose reagent area of N-Multistix. We hope that the report of such false-positive results would encourage the manufacturers to minimize allinterferences in these widely used test strips; we also want to stress that measurement of the urinary iodine concentration should be done with samples that have not been contaniinated by previous immersion of dipsticks.
منابع مشابه
Urine test strips as a source of iodine contamination.
In the course of conducting an analysis in a subset of the controlled antenatal thyroid screening study (1) samples, we recently noted that some urine samples from pregnant women in Wales, a region known to be iodine deficient, had urinary iodine concentrations in excess of 500mg=L. We suspected contamination from urine test strips. We obtained Combur Test D urine test strips (Roche Diagnostics...
متن کاملHigh willingness to use rapid fentanyl test strips among young adults who use drugs
BACKGROUND Synthetic opioid overdose mortality among young adults has risen more than 300% in the USA since 2013, primarily due to the contamination of heroin and other drugs with illicitly manufactured fentanyl. Rapid test strips, which can be used to detect the presence of fentanyl in drug samples (before use) or urine (after use), may help inform people about their exposure risk. The purpose...
متن کاملIn vitro and in vivo interaction of oral contraceptive high dose (HD) with urine morphine diagnostic test
Introduction: Urine morphine test, in several countries is the most primarily available qualitative test for detecting opioid abusers. Since the users of illicit drugs attempt to defeat urine tests and there are also plenty of claims that usage of HD (high dose) contraceptive pills can result in false-negative results, we decided to design the present study to investigate the probable in vit...
متن کاملUrine Test Strips
Procedure and Notes • Use only well mixed, non-centrifuged urine, which should not be older than 4 hours. First morning urine is recommended. Protect the samples from light. • If the samples cannot be tested immediately, they should be stored at 2...4°C and brought to room temperature (15...25°C) before testing. • Collect specimen in clean, well rinsed containers, free of detergents. Do not add...
متن کاملReliability of studies of iodine intake and recommendations for number of samples in groups and in individuals.
The iodine intake level in a population is determined in cross-sectional studies. Urinary iodine varies considerably and the reliability of studies of iodine nutrition and the number of samples needed is unsettled. We performed a longitudinal study of sixteen healthy men living in an area of mild to moderate iodine deficiency. Iodine and creatinine concentrations were measured in spot urine sam...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 33 10 شماره
صفحات -
تاریخ انتشار 1987