This paper presents an active crowbar, constructed with silicon controlled rectifiers (SCRs), for doubly fed induction generator (DFIG)-based wind turbines to fulfill low-voltage ride-through (LVRT) requirements demanded by grid codes. By this design, not only the active deactivation of the costly IGBT crowbar, replacing the passive crowbar for this ability, can be achieved with the more cost-effective SCRs, but also the reliability of the circuit is strengthened thanking to the high surge capability of SCR. In this topology, three back-to-back SCR switches are connected in delta form and further engaged with the rotor circuit of DFIG through power dissipation resistors, working as the main circuit of crowbar, while the rotor side converter (RSC) is used to commutate the SCRs at the desired deactivation moment to disconnect the crowbar, allowing for resumption of the feedback control to DFIG. By this topology the harmonics introduced into the rotor circuit by the diode bride in the IGBT crowbar are got rid of and by this commutation method the overvoltage risk at turning off the IGBT is eliminated. With the simulative results on a 2 MW DFIG, the comparison with the IGBT crowbar is made. The feasibility of the proposed crowbar technique is further demonstrated with experiments on a laboratory-scale test rig. 2016 Elsevier Ltd. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Differential Evolution Based IDWNN Controller for Fault Ride-Through of Grid-Connected Doubly Fed Induction Wind Generators

The key objective of wind turbine development is to ensure that output power is continuously increased. It is authenticated that wind turbines (WTs) supply the necessary reactive power to the grid at the time of fault and after fault to aid the flowing grid voltage. At this juncture, this paper introduces a novel heuristic based controller module employing differential evolution and neural netw...

متن کامل

Fault Behavior of Wind Turbines

Synchronous generators have always been the dominant generation type in the grid. This fact affected both planning and operation of power systems. With the fast increase of wind power share in the grid in the last decade, the situation is changing. In some countries wind power represents already a consistent amount of the total generation. Wind turbines can be classified as non-synchronous gene...

متن کامل

Control and Simulation of a Crowbar Protection for DFIG Wind Turbine during Power Systems Disturbance

The use of the doubly fed induction generator (DFIG) in modern variable-speed wind turbines has increased rapidly. According to the new grid code requirements, wind turbines generators must remainconnected to the grid during grid disturbances so crowbar protections systems is being used to protect the DFIG, this paper introduces a comparison between conventional crowbar protection, series crowb...

متن کامل

Behavior of DFIG Wind Turbines with Crowbar Protection under Short Circuit

Doubly Fed Induction Generators DFIG are nowadays widely used in variable speed wind power plants. The dynamic interaction between variable speed DFIG wind turbines and the power system which is subjected to disturbances, such as short circuit faults, is an important issue. The ability of the wind power plant to stay connected to the grid during disturbances is important to avoid a cascading ef...

متن کامل

A Novel Crowbar Protection Technique for DFIG Wind Farm during Fault Ride Through

This paper proposes a terminal crowbar protection technique for Doubly Fed Induction Generators (DFIG) to protect the rotor converter and enhance network stability during grid disturbances. Simulation test using MATLAB-Simulink toolbox is implemented on a 9 MW wind farm exports its power to 120 KV grid. The simulation is performed using different values of crowbar resistances. The variations of...