Feasibility study on image guided patient positioning for stereotactic body radiation therapy of liver malignancies guided by liver motion

نویسندگان

  • Christian Heinz
  • Sabine Gerum
  • Philipp Freislederer
  • Ute Ganswindt
  • Falk Roeder
  • Stefanie Corradini
  • Claus Belka
  • Maximilian Niyazi
چکیده

BACKGROUND Fiducial markers are the superior method to compensate for interfractional motion in liver SBRT. However this method is invasive and thereby limits its application range. In this retrospective study, the compensation method for the interfractional motion using fiducial markers (gold standard) was compared to a new non-invasive approach, which does rely on the organ motion of the liver and the relative tumor position within this volume. METHODS We analyzed six patients (3 m, 3f) treated with SBRT in 2014. After fiducial marker implantation, all patients received a treatment CT (free breathing, without abdominal compression) and a 4D-CT (consisting of 10 respiratory phases). For all patients the gross tumor volumes (GTVs), internal target volume (ITV), planning target volume (PTV), internal marker target volumes (IMTVs) and the internal liver target volume (ILTV) were delineated based on the CT and 4D-CT images. CBCT imaging was used for the standard treatment setup based on the fiducial markers. According to the patient coordinates the 3 translational compensation values (t x , t y , t z ) for the interfractional motion were calculated by matching the blurred fiducial markers with the corresponding IMTV structures. 4 observers were requested to recalculate the translational compensation values for each CBCT (31) based on the ILTV structures. The differences of the translational compensation values between the IMTV and ILTV approach were analyzed. RESULTS The magnitude of the mean absolute 3D registration error with regard to the gold standard overall patients and observers was 0.50 cm ± 0.28 cm. Individual registration errors up to 1.3 cm were observed. There was no significant overall linear correlation between the respiratory motion and the registration error of the ILTV approach. CONCLUSIONS Two different methods to calculate the translational compensation values for interfractional motion in stereotactic liver therapy were evaluated. The registration accuracy of the ILTV approach is mainly limited by the non-rigid behavior of the liver and the individual registration experience of the observer. The ILTV approach lacks the accuracy that would be desired for stereotactic radiotherapy of the liver.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[Availability of using diaphragm matching in stereotactic body radiotherapy (SBRT) at the time in breath-holding SBRT for liver cancer].

PURPOSE Liver image guided radiation therapy (IGRT) based on bone matching risks generating serious target positioning errors for reasons of lack of reproducibility of expiration breath hold. We therefore investigated the feasibility of 3D image matching between planning CT images and pretreatment cone-beam computed tomography (CBCT) images based on diaphragm surface matching. METHOD 27 liver...

متن کامل

Fiducial Placement for Stereotactic Body Radiation Therapy under Only Endoscopic Ultrasonography Guidance in Pancreatic and Hepatic Malignancy: Practical Feasibility and Safety

BACKGROUND/AIMS Stereotactic body radiation therapy (SBRT) for gastrointestinal malignancies requires the placement of fiducials to guide treatment delivery. This study aimed to determine the safety and technical feasibility of endoscopic ultrasonography (EUS)-guided fiducial placement for SBRT. METHODS From November 2010 to August 2012, 32 consecutive patients who were scheduled to receive S...

متن کامل

A fast model for prediction of respiratory lung motion for image-guided radiotherapy: A feasibility study

Background: The aim of this work was to study the feasibility of constructing a fast thorax model suitable for simulating lung motion due to respiration using only one CT dataset. Materials and Methods: For each of six patients with different thorax sizes, two sets of CT images were obtained in single-breath-hold inhale and exhale stages in the supine position. The CT images were then ...

متن کامل

The Impact of Residual Geometric Inaccuracies on Normal Organ Doses in Image Guided-Radiation Therapy of Prostate Cancer Using On-Board Kilovoltage Cone-Beam Computed Tomography

Introduction: The aim of this retrospective study was to evaluate the variations in delivered dose to the bladder, rectum, and femoral heads of prostate cancer patients during a course of treatment by image-guided radiation therapy (IGRT). Materials and Methods: Overall, 15 patients with prostate cancer were selected and. Each week, for each patient five consecutive cone beam computed tomograph...

متن کامل

Evaluation of inter- and intrafractional motion of liver tumors using interstitial markers and implantable electromagnetic radiotransmitters in the context of image-guided radiotherapy (IGRT) – the ESMERALDA trial

BACKGROUND With the development of more conformal and precise radiation techniques such as Intensity-Modulated Radiotherapy (IMRT), Stereotactic Body Radiotherapy (SBRT) and Image-Guided Radiotherapy (IGRT), patients with hepatic tumors could be treated with high local doses by sparing normal liver tissue. However, frequently occurring large HCC tumors are still a dosimetric challenge in spite ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2016