Thin-Walled Cross-Linked Acetabular Liners Need Not Exhibit Reduced Locking Strength.
نویسندگان
چکیده
Use of larger diameter femoral heads has emerged as a promising strategy to reduce the risk of dislocation after total hip arthroplasty, but thinning the walls of cross-linked ultra-high-molecular-weight polyethylene (UHMWPE) acetabular liners to accommodate these larger heads may compromise the locking mechanism of the liner. The purpose of this study was to test the mechanical integrity of the locking mechanism in cross-linked and re-melted UHMWPE acetabular components with reduced wall thickness. The locking mechanism of cross-linked (100 kGy/re-melted) acetabular liners in sizes 50/28, 50/36, and 52/36 mm of 1 design was evaluated by lever-out tests and torsion tests. Torsion tests were performed at 2 angles to isolate the liner's locking tabs independent of the contribution of its central post. Lever-out testing demonstrated nominally reduced failure strength in 50/36-mm liners (13.3 N · m) compared with 50/28-mm liners (12.3 N · m; P=.0502), whereas the lever-out strength of 52/36-mm liners was 12.2±0.94 N · m. Failure torques were similar between 50/28- and 50/36-mm liners at 45° and 90°, but the failure torque of size 52/36-mm liners was significantly higher at each angle. The use of larger diameter femoral heads does not compromise the locking mechanism of thinned MicroSeal (Signal Medical Corp, Marysville, Michigan) acetabular liners. Use of a cross-linked UHMWPE acetabular liner, with a locking mechanism that is not compromised when the liner is thinned to a thickness of at least 2.86 mm, appears to be a biomechanically sound construct when articulated with large diameter femoral heads.
منابع مشابه
Rim cracking of the cross-linked longevity polyethylene acetabular liner after total hip arthroplasty.
BACKGROUND Studies have suggested that cross-linked polyethylene bearings reduce wear rates from 40% to 100% compared with conventional polyethylene. However, the reduced mechanical properties of highly cross-linked polyethylene have the potential to be a limiting factor in device performance. We reviewed a series of retrieved acetabular liners with a fracture of the superior rim to assess the ...
متن کاملRetrieval Analysis of Sequentially Annealed Highly Crosslinked Polyethylene Used in Total Hip Arthroplasty
BACKGROUND First-generation annealed and second-generation sequentially annealed, highly crosslinked polyethylenes (HXLPEs) have documented reduced clinical wear rates in their first decade of clinical use compared with conventional gamma inert-sterilized polyethylene. However, for both types of annealed HXLPE formulations, little is known about their reasons for revision, their in vivo oxidati...
متن کاملHighly cross-linked polyethylene acetabular liners retrieved four to five years after revision surgery: a report of two cases.
There is currently considerable interest in the use of highly cross-linked polyethylene (XLPE) acetabular liners for total hip arthroplasty (THA). In literature, only a single retrieval analysis of one type of XLPE liner implanted for greater than four years exists. The purpose of the present report is to quantify surface deviations in two XLPE liners implanted during revision THA and retrieved...
متن کاملRadiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement.
BACKGROUND Radiostereometric analysis provides highly precise measurements of component micromotion relative to the bone that is otherwise undetectable by routine radiographs. This study compared, at a minimum of five years following surgery, the micromotion of tantalum and titanium acetabular cups and femoral head penetration in highly cross-linked polyethylene liners and conventional (ultra-h...
متن کاملBackside Wear Analysis of Retrieved Acetabular Liners with a Press-Fit Locking Mechanism in Comparison to Wear Simulation In Vitro
Backside wear due to micromotion and poor conformity between the liner and its titanium alloy shell may contribute to the high rates of retroacetabular osteolysis and consequent aseptic loosening. The purpose of our study was to understand the wear process on the backside of polyethylene liners from two acetabular cup systems, whose locking mechanism is based on a press-fit cone in combination ...