Measurement of laser intensities approaching 10 W/cm with an accuracy of 1%
نویسندگان
چکیده
M. G. Pullen, W. C. Wallace, D. E. Laban, A. J. Palmer, G. F. Hanne, A. N. Grum-Grzhimailo, K. Bartschat, I. Ivanov, A. Kheifets, D. Wells, H. M. Quiney, X. M. Tong, I. V. Litvinyuk, R. T. Sang, and D. Kielpinski1,2∗ ARC Centre of Excellence for Coherent X-ray Science, Griffith University, Nathan, Australia Australian Attosecond Science Facility and Centre for Quantum Dynamics, Griffith University, Nathan, Australia Atomic and Electronics Physics Group, Westfälische Wilhelms-Universität, D-48149 Münster, Germany Skobeltsyn Institute of Nuclear Physics, Lomonosov Moscow State University, Moscow 119234, Russia Department of Physics and Astronomy, Drake University, Des Moines, Iowa 50311, USA Research School of Physical Sciences, The Australian National University, Canberra, Australia ARC Centre of Excellence for Coherent X-ray Science, University of Melbourne, Melbourne, Australia and Division of Materials Science, Faculty of Pure and Applied Sciences, and Center for Computational Science, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8577, Japan (Dated: April 5, 2013)
منابع مشابه
The effect of self-absorption correction using internal reference on determining heavy metals concentration by laser induced breakdown spectroscopy
The identification and concentration of heavy metals, which may be so harmful for the body, is determined by the method of calibration-free laser-induced breakdown spectroscopy using a special strategy. First, the plasma temperature is obtained using the Boltzmann plot. Then, a line with an inappreciable self-absorption is considered for each element as the reference. The modified intensities o...
متن کاملCosta 2 . 1 Millimeter - Wave Frequency Measurement of the Rydberg Constant
The Rydberg constant, R., relates the wavelengths of the spectrum of atomic hydrogen to practical laboratory units. As such, R. is the natural unit for measurements of many atomic properties. Recent advances in optical wavelength metrology have enabled experiments using laser spectroscopy to measure R. with accuracy approaching 2 parts in 1011.4 While R. remains the most accurately measured fun...
متن کاملError Analysis, Design and Modeling of an Improved Heterodyne Nano-Displacement Interferometer
A new heterodyne nano-displacement with error reduction is presented. The main errors affecting the displacement accuracy of the nano-displacement measurement system including intermodulation distortion error, cross-talk error, cross-polarization error and phase detection error are calculated. In the designed system, a He-Ne laser having three-longitudinal-mode is considered as the stabiliz...
متن کاملاندازهگیری ضریب شکست غیر خطی در شیشههای آلاییده به بلورهای نیمرسانا
There are several techniques in use for non-linear refractive index measurement, namely, interferometric techniques, in which conventional inter-ferometers are used, degenerate for wave mixing (DFWM), and z-scan, Each of these techniques suffers from some shortcmings. For example conventional interferometers like Fabry-Perot and Twyman-Green need high quality optical components, unwanted refl...
متن کاملRadiation Reaction of Electrons at Laser Intensities up to 10 Xilin Zhou
Recent developments in high-power laser technology allowing for laser intensities from 10 22 W/cm 2 up to 10 24 W/cm 2 have opened up the study of the super-intense laser acceleration of electrons to tens of GeV energies. These intensities may be attainable in the next generation of super-powerful lasers such as EP-OPAL, a proposed extension of the Laboratory for Laser Energetics OMEGA EP Laser...
متن کامل