Refuge alternatives relief valve testing and design.

نویسندگان

  • T J Lutz
  • P T Bissert
  • G T Homce
  • J A Yonkey
چکیده

The U.S. National Institute for Occupational Safety and Health (NIOSH) has been researching refuge alternatives (RAs) since 2007. RAs typically have built-in pressure relief valves (PRVs) to prevent the unit from reaching unsafe pressures. The U.S. Mine Safety and Health Administration requires that these valves vent the chamber at a maximum pressure of 1.25 kPa (0.18 psi, 5.0 in. H2O), or as specified by the manufacturer, above mine atmospheric pressure in the RA. To facilitate PRV testing, an instrumented benchtop test fixture was developed using an off-the-shelf centrifugal blower and ductwork. Relief pressures and flow characteristics were measured for three units: (1) a modified polyvinyl chloride check valve, (2) an off-the-shelf brass/cast-iron butterfly check valve and (3) a commercially available valve that was designed specifically for one manufacturer's steel prefabricated RAs and had been adapted for use in one mine operator's built-in-place RA. PRVs used in tent-style RAs were not investigated. The units were tested with different modifications and configurations in order to check compliance with Title 30 Code of Federal Regulations, or 30 CFR, regulations. The commercially available relief valve did not meet the 30 CFR relief pressure specification but may meet the manufacturer's specification. Alternative valve designs were modified to meet the 30 CFR relief pressure specification, but all valve designs will need further design research to examine survivability in the event of a 103 kPa (15.0 psi) impulse overpressure during a disaster.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In-mine Experimental Investigation of Temperature Rise and Development of a Validated Thermal Simulation Model of a Mobile Refuge Alternative

Mine Safety and Health Administration (MSHA) regulations require underground coal mines to use refuge alternatives (RAs) to provide a breathable air environment for 96 hrs. One of the main concerns with the use of mobile RAs is the heat and humidity buildup inside the RA. The accumulation of heat and humidity can result in miners suffering heat stress or even death. To investigate this issue, t...

متن کامل

Validation of temperature and humidity thermal model of 23-person tent-type refuge alternative.

U.S. Mine Safety and Health Administration (MSHA) regulations require underground coal mines to use refuge alternatives (RAs) to provide a breathable air environment for 96 hours. One of the main concerns with the use of mobile RAs is heat and humidity buildup inside the RA. The accumulation of heat and humidity can result in miners suffering heat stress or even death. MSHA regulations require ...

متن کامل

Pressure Relief Valve Selection

Pressure relief valve is one of the most important devices used on the security of pipelines, since it is responsible to guarantee the integrity of the installations. Generally, the response and behavior of a relief valve during its transient is unknown by users, who employ simplified and static analysis to design the pipeline, further, the information provided by manufactures is limited. The f...

متن کامل

Health-Related Quality of Life after Valve Replacement Surgery

Background: Heart valve disease gradually increases the pressure in the heart chambers and impairs heart pumping. It influences on quality of life due to low output, disability, fear, amnesia, anxiety, and depression. Although most of signs and symptoms in patients with heart valve diseases may significantly decrease after valve replacement surgery, there is limited information about the impact...

متن کامل

2-D Dynamic Analysis of a Pressure Relief Valve by CFD

This paper presents a study of dynamic characteristics of spring loaded relief valve and the turbulent flow of water through it by using CFD in 2-Dimensions. Mesh deformation due to the fluid-solid interaction between the valve disc and the surrounding fluid and CEL expressions determined by solving a dynamics equation of forces acting on the valve disc, are used to account for the motion of th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Mining engineering

دوره 68 10  شماره 

صفحات  -

تاریخ انتشار 2016