Implant-supported first molar restorations: correlation of finite element analysis with clinical outcomes.
نویسندگان
چکیده
PURPOSE This study aimed to evaluate the effect of the placement of wide-diameter implants on bone stress concentrations and marginal bone loss in the first molar region. Study hypotheses held that increasing implant diameter would decrease peri-implant bone stress levels, but that statistically significant reductions in clinical bone loss would either (1) not be observed for any implant diameter or (2) be observed only for the widest implant diameter. MATERIALS AND METHODS Three-dimensional finite element analysis (3D FEA) was used to analyze the relationship between implant diameter and peri-implant bone thickness, cortical bone thickness, occlusal load direction, and percentage of boneto-implant contact on bone stress levels in the first molar region. A retrospective review of patient records was also conducted in three private practices to assess clinical outcomes and bone level changes around one implant design in three diameters (3.7, 4.7, and 6.0 mm) placed in first molar locations. Categorical variable summaries and comparisons of 3D FEA and clinical findings were made using the FREQ procedure, t test procedures (Student t tests, folded F tests, Satterthwaite t tests), and the NONPAR1WAY procedure (Wilcoxon nonparametric test). RESULTS Cumulative implant success was 98.4% and survival was 98% after a mean of 49.2 months. Although increasing implant diameter always reduced peri-implant stress concentrations in 3D FEA experiments, clinically, only 6.0-mm implants exhibited a statistically significant reduction in bone loss (0 mm) as compared to 3.7-mm and 4.7-mm implants. CONCLUSION Only 6.0-mm implants were effective in reducing marginal bone loss in the first molar region. 3D FEA results supported previous clinical findings that maintaining approximately 1.8 mm of buccal plate thickness can help reduce bone stress concentrations and preserve buccal bone height. A history of periodontitis may adversely affect long-term marginal bone stability.
منابع مشابه
Finite Element Analysis of the Effect of Proximal Contour of Class II Composite Restorations on Stress Distribution
Introduction: The aim of this study was to evaluate the effect of proximal contour of class II composite restorations placed with straight or contoured matrix band using composite resins with different modulus of elasticity on stress distribution by finite element method. Methods: In order to evaluate the stress distribution of class II composite restorations using finite element method, upper ...
متن کاملThe effect of implant angulation and splinting on stress distribution in implant body and supporting bone: A finite element analysis
OBJECTIVE The aim of this study was to investigate the influence of implant crown splinting and the use of angulated abutment on stress distribution in implant body and surrounding bone by three-dimensional finite element analysis. MATERIALS AND METHODS For this study, three models with two implants at the site of mandibular right second premolar and first molar were designed (1): Both implan...
متن کاملEvaluation of stress distributions in peri-implant and periodontal bone tissues in 3- and 5-unit tooth and implant-supported fixed zirconia restorations by finite elements analysis
OBJECTIVE In this study, it is aimed to compare the distribution of stress on periodontal and peri-implant bone tissues in 3- and 5-unit-dental and implant-supported zirconia restorations using finite element analysis. MATERIALS AND METHODS Stress distribution formed in periodontal and peri-implant bone tissues as a result of chewing forces was analyzed in dental and implant-supported three-d...
متن کاملStress distribution pattern of screw-retained restorations with segmented vs. non-segmented abutments: A finite element analysis
Background. Screw-retained restorations are favored in some clinical situations such as limited inter-occlusal spaces. This study was designed to compare stresses developed in the peri-implant bone in two different types of screw-retained restorations (segmented vs. non-segmented abutment) using a finite element model. Methods. An implant, 4.1 mm in diameter and 10 mm in length, was placed in t...
متن کاملتعیین توزیع تنش استخوان اطراف ایمپلنتهای فک پایین در طرحهای مختلف پروتز به هنگام Mandibular- Flexure
Statement of Problem: In the treatment of edentulous patients with implant supported fixed partial dentures several factors such as implant numbers, implant position, superstructure pattern and cantilever length must be considered. Mandibular flexture in function exerts forces in peri-implant bone, however this phenomenon has received little attention. Purpose: The goal of this finite element a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The International journal of oral & maxillofacial implants
دوره 27 1 شماره
صفحات -
تاریخ انتشار 2012