In Water Thermal Imaging Comparison of the Alcon Legacy and AMO Sovereign Phacoemulsification Systems§

نویسندگان

  • Kevin M Miller
  • Michael D Olson
چکیده

PURPOSE To compare the temperature profiles of 2 popular phacoemulsification units under similar operating conditions in water. METHODS The phacoemulsification probes of the Sovereign WhiteStar and Legacy AdvanTec were capped with water-filled test chambers and imaged side-by-side using a thermal camera. The highest temperature of each chamber was measured at several time points after power application. Testing was performed under conditions capable of producing a corneal burn. The Legacy was operated in pulse mode at 15 Hz; a 50% duty cycle; and console power settings of 10, 30, 50 and 100%. The Sovereign was operated at the same console settings in WhiteStar C/F pulse mode at 56 Hz and a 33% duty cycle. RESULTS Under all conditions (powers of 10, 30, 50 and 100%; with or without irrigation/aspiration flow; and with or without sleeve compression), the Sovereign generated higher temperatures than the Legacy. At irrigation/aspiration flow rates ≥ 5 cc/min, the temperature profiles of the 2 units were indistinguishable. CONCLUSION The Sovereign WhiteStar ran hotter than the Legacy AdvanTec under a variety of controlled low flow operating conditions. The Sovereign WhiteStar is more likely than the Legacy AdvanTec to produce a corneal burn under low flow conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparing the effect of two different intraocular lenses on optical aberrations in bilaterally operated eyes for cataract

OBJECTIVE To assess high order and spherical aberrations results of hydrophobic acrylic AMO Sensar AR40E and hydrophobic acrylic Alcon AcrySof SA60AT intraocular lenses after implantation in cases with bilateral cataract. METHODS Cases diagnosed as bilateral cataract were included in the study and preoperative aberration measurements were recorded by using Nidek OPD SCAN-ARK 1000. Groups were...

متن کامل

Thermal characterization of phacoemulsification probes operated in axial and torsional modes.

PURPOSE To analyze temperature increases and identify potential sources of heat generated when sleeved and sleeveless phacoemulsification probes were operated in axial and torsional modes using the Infiniti Vision System with the Ozil torsional handpiece. SETTING Phacodynamics Laboratory, Pasteur Ophthalmic Clinic, Santiago, Chile. DESIGN Experimental study. METHODS Two computer-controlle...

متن کامل

Worldwide survey highlights current cataract surgery practice trends

CLINICAL practice patterns of European and US cataract surgeons are becoming more similar, although some interesting and important differences continue to distinguish the two groups, according to David Leaming MD. Dr Leaming will present a comparison study of practice styles of European and American surgeons at the XXII Congress of the ESCRS in Paris. He will compare the responses of 964 US sur...

متن کامل

Volume-based characterization of postocclusion surge.

PURPOSE To propose an alternative method to characterize postocclusion surge using a collapsible artificial anterior chamber to replace the currently used rigid anterior chamber model. SETTING Fundación Oftamológica Los Andes, Santiago, Chile. METHODS The distal end of a phacoemulsification handpiece was placed inside a compliant artificial anterior chamber. Digital recordings of chamber pr...

متن کامل

Toric intraocular lenses for correction of astigmatism in keratoconus and after corneal surgery

PURPOSE To describe the results of cataract extraction with toric intraocular lens (IOL) implantation in patients with preexisting astigmatism from three corneal conditions (keratoconus, postkeratoplasty, and postpterygium surgery). METHODS Cataract patients with topographically stable, fairly regular (although sometimes very high) corneal astigmatism underwent phacoemulsification with implan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2008