Pseudofusion in a dual chamber pacemaker: Is this pacemaker working properly?

نویسندگان

  • Mohammad Ali Akbarzadeh
  • Abolfath Alizadeh
  • Negar Bahrololoumi Bafruee
چکیده

A 57-year-old womanwith a history of dizziness due to episodes of complete heart block and bradycardia was referred to the electrophysiology ward for pacemaker implantation. A dual chamber pacemaker (Medtronic, Relia, Medtronic, Minneapolis, USA) was implanted. Its analysis showed normal function (atrial lead capture threshold 0.5 V at 0.4 ms, ventricular lead capture threshold 0.75 V at 0.4 ms, and P-wave and R wave amplitude sensing 2 mV and 8mV, respectively). The pacemaker was programmed in the DDDR mode with a lower rate limit of 60 bpm, atrial and ventricular output of 3.5 V and 3.5 V at 0.4 ms respectively, atrial and ventricular sensitivity of 0.5 mV and 2.8 mV respectively, a paced atrioventricular interval (pAVI) of 180 ms, and a sensed atrioventricular interval of 150 ms. The post atrioventricular blanking period (PAVBP) was 60 ms. In the first day after implantation, 12-lead electrocardiography showed episodes of pseudofusion, leading to suspicion of pacemaker malfunction (Fig. 1).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pacemaker lead endocarditis with hiccups (Kalayci)

Background: Lead-related infections that might develop after pacemaker implantation associated with high mortality and morbidity rates are challenging to manage and pose high-cost. Patients with lead-related infections usually present with fever, chills and fatigue and the treatment can be challenging unless the implant system is extracted. Case presentation: A 66-year old male patient who und...

متن کامل

A novel non invasive measurement of hemodynamic parameters: Comparison of single-chamber ventricular and dual-chamber pacemaker

We carried out a cross sectional study to analyze hemodynamic parameters of single-chamber ventricular pacemaker compared with dual-chamber pacemaker by using thoracic electrical bioimpedance monitoring method (Physio FlowTM) a novel simple non-invasive measurement. A total of 48 consecutive outpatients comprised of 27 single chamber pacemaker and 21 dual chamber were analyzed. We measured card...

متن کامل

Wide complex tachycardia in a patient with a dual chamber pacemaker.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . doi:10.1093/europace/eun312 Online publish-ahead-of...

متن کامل

Design and Analysis of Academic Dual Chamber Pacemakers

In this paper, we describe a relatively inexpensive framework for the design of an academic dual chamber pacemaker that can be used to empirically analyze different pacemaker designs. The goal of this framework is to provide a convenient platform that can be used for research and teaching in realtime embedded system design. The framework can also be used for model-driven development of pacemake...

متن کامل

Pacemaker Twiddler's Syndrome

A 76-yr-old man with unipolar ventricular pacemaker, previously implanted in the right ventricular apex, presented with syncopal attack and twitching of the right pectoralis muscle. He finally was diagnosed as having Twiddler's syndrome. The patient had a pulse rate of 36/min and cannon waves in the neck veins. Chest radiography showed a dislodged pacing lead completely wrapped around the pulse...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of arrhythmia

دوره 32 2  شماره 

صفحات  -

تاریخ انتشار 2016