BACKGROUND The main complications of PTCA remain thrombosis and restenosis. Recent studies have demonstrated reduction in the neointimal hyperplasia after intracoronary radiation (IR) with doses of 10 to 25 Gy of ionizing radiation delivered by either beta- or gamma-emitters to injured vessels. The purpose of this study was to examine the effect of ionizing radiation on the thrombosis rate (TR) of injured porcine coronary arteries. METHODS AND RESULTS Thirty-four juvenile swine (63 coronary arteries) were subjected to overstretch balloon injury followed by IR with doses of 0 to 18 Gy of either beta- or gamma-radiation. Two weeks after treatment, tissue sections were perfusion-fixed, stained with hematoxylin-eosin and Verhoeff-van Gieson's stain, and analyzed for presence of a thrombus, thrombus morphology, and neointima formation by computer-assisted histomorphometry techniques. Although the overall TR increased dose-dependently from 0 to 18 Gy prescribed dose, luminal thrombi decreased. Thrombus area also decreased with increasing radiation dose, whether assessed at the prescription point or at the luminal surface, which corresponded to decreased intimal area. Furthermore, luminal thrombi present after IR tended to consist mostly of fibrin and thus were less organized than in controls. CONCLUSIONS These results suggest that IR induces thrombosis but does not necessarily compromise the lumen. Strategies for reducing TR may further decrease intimal area as well as increasing the safety of this therapy.
منابع مشابه
Vascular repair after balloon overstretch injury in porcine model effects of intracoronary radiation.
OBJECTIVES The purpose of this study was to evaluate the effect of IR on thrombus formation and dissection repair following overstretch balloon injury in porcine coronary arteries. BACKGROUND Exposure of blood to the injured arterial wall after percutaneous transluminal coronary angioplasty (PTCA) induces thrombus formation and inflammation in the dissection plane. Neointima formation is rela...
متن کاملLong-term effects of intracoronary beta-radiation in balloon- and stent-injured porcine coronary arteries.
BACKGROUND The data on the long-term safety and efficacy of intracoronary beta-radiation in animal models are limited. METHODS AND RESULTS A total of 30 coronary arteries in 15 swine were subjected to balloon or stent injury followed by beta-radiation from a centered 32P source (2000 cGy to 1 mm beyond lumen surface) or a sham radiation procedure. The animals received aspirin for 6 months and...
متن کاملIntrapericardial ethanol delivery inhibits neointimal proliferation after porcine coronary overstretch.
BACKGROUND Previous work has shown that ethanol dampens cell growth signals and inhibits smooth muscle proliferation in a restenosis model. Catheter-based approaches to intrapericardial (IPC) delivery of therapeutic agents have been recently demonstrated to be feasible. This study tested the effect of IPC instillation of ethanol on the injury response of overstretched porcine coronary arteries....
متن کاملRadioactive 133-Xenon Gas-Filled Balloon to Prevent Restenosis
Background—Ionizing radiation administered intraluminally via catheter-based systems using solid and sources or liquid-filled balloons has shown reduction in the neointima formation after injury in the porcine model. We propose a novel system that uses a 133-Xenon (Xe) radioactive gas-filled balloon catheter system. Methods and Results—Overstretch balloon injury was performed in the coronary ar...
متن کاملRadioactive 133-Xenon gas-filled balloon to prevent restenosis: dosimetry, efficacy, and safety considerations.
BACKGROUND Ionizing radiation administered intraluminally via catheter-based systems using solid beta and gamma sources or liquid-filled balloons has shown reduction in the neointima formation after injury in the porcine model. We propose a novel system that uses a 133-Xenon (133Xe) radioactive gas-filled balloon catheter system. METHODS AND RESULTS Overstretch balloon injury was performed in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation