Dialysis-assisted fiber optic spectroscopy for in situ biomedical sensing.
نویسندگان
چکیده
A miniature fiber optic spectrometer enclosed within a semipermeable (dialysis) membrane is proposed for in vivo interstitial sensing applications. The semipermeable membrane acts as a molecular filter, allowing only small molecules to pass through to the sampling volume. This filtering, in principle, should enable continuous in vivo drug sensing, removing the necessity for complex microdialysis systems. We use a biological phantom to examine the reliable detection of a fluorescence signal from small dye molecules in the presence of large fluorophores and scatterers. We find that spectral artefacts arising from scatterers and large fluorophores are substantially suppressed, simplifying the spectral analysis. In addition, the measured sampling rate of 157 s is superior to existing in vivo tissue assaying techniques such as microdialysis, which can take tens of minutes.
منابع مشابه
Fiber optic probes for biomedical optical spectroscopy.
Fiber optic probes are a key element for biomedical spectroscopic sensing. We review the use of fiber optic probes for optical spectroscopy, focusing on applications in turbid media, such as tissue. The design of probes for reflectance, polarized reflectance, fluorescence, and Raman spectroscopy is illustrated. We cover universal design principles as well as technologies for beam deflecting and...
متن کاملFiber - Optic Sensing of Linear Thermal Expansion (RESEARCH NOTES)
The use of a LED fiber-optic sensor to measure displacement and linear thermal expansion is described. It has a sensitivity of about 0.6 mV/mm, a resolution of 1.25 mm, and a dynamic rang of 400 mm for displacement measurements. For thermal expansion, it shows a sensitivity of about 3.5 mV/C, and the experimental linear expansion values are in agreement with those calculated. The reported senso...
متن کاملCOMPARISON OF DIFFERENT GLASS COMPOUNDS FOR INTRINSIC FIBER OPTIC TEMPERATURE SENSORS
Different glasses suitable for temperature sensing in the fiber optic sensors were studied in this article. The phase changes for eight different glass materials were calculated and results were compared. Our results showed that extra dense flint glass is the most sensitive one, while pure silica results in the lowest phase change. In another study the effect of wavelength on the phase variatio...
متن کاملQuantification of in vivo fluorescence decoupled from the effects of tissue optical properties using fiber-optic spectroscopy measurements.
We present a method for tissue fluorescence quantification in situ using a handheld fiber optic probe that measures both the fluorescence and diffuse reflectance spectra. A simplified method to decouple the fluorescence spectrum from distorting effects of the tissue optical absorption and scattering is developed, with the objective of accurately quantifying the fluorescence in absolute units. T...
متن کاملTapered Optical Fiber Coated with ZnO Nanorods for Detection of Ethanol Concentration in Water
This work presents ZnO nanorods coated multimode optical fiber sensing behavior in response to ethanol solution. The sensor operates based on modulation of light intensity which arises from manipulation of light interaction with the ambient environment in sensing region. For this purpose, two steps are experimentally applied here; etching and then coating fiber with ZnO nanorods to provide stro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomedical optics
دوره 11 1 شماره
صفحات -
تاریخ انتشار 2006