Measuring Cbv by the Recirculation Part of Dynamic Susceptibility Contrast Mri on Rat Model

نویسندگان

  • Y-L. Wu
  • C-C. Chen
  • Y-C. Wu
  • C-H. Chang
چکیده

Introduction By using the Dynamic Susceptibility Contrast (DSC) method for MR perfusion imaging, relative cerebral blood volume maps are obtained from integrating the first pass area of the local tissue concentration time curve CT(t). However, because of relatively high heart rate and fast circulation in small animal experiments, CT peak changes quickly and results in only few data points for quantification. In this work, we investigated the feasibilities of using the recirculation part of CT for assessing CBV. Relative CBV maps of normal rats’ first pass and recirculation of Gd-DTPA bolus were compared. Furthermore, additional rCBV maps by administration of monocrystalline iron oxide nanoparticles (MION), which features high susceptibility effect and long plasma half-life, were also generated as proportional references for relative quantifications. Materials and Method According to the principles of DSC perfusion imaging, the area under the first pass curve of the Gd-DTPA CT function is proportional the CBV times the integral of arterial input function.[1] After first passing, the contrast agent bolus is dispersed by pulmonary and system circulations before re-circulating to tissue, and CT becomes a stable decreasing function with low concentration. This “recirculation” part of CT is usually removed when assessing the CBV value. However, by assuming the AIF as a gradually decreasing function, the area of recirculation is proposed as an alternative index for relative CBV quantification in this study. For small animal imaging, the recirculation CBV can be calculated from more data points in longer duration than the first pass CBV map, and therefore supposed to be less affected by the noise and insufficient sampling rate of applied MRI sequences. In this study, three normal male Sprague-Dawley rats (mean weight of 314.3±38.9g) were anesthetized with 1.5% Isoflurane and scanned in a 4.7T animal MRI scanner (Bruker Biospec 47/40). For DSC imaging, 150 consecutive multi-slice gradient echo EPI scans were applied with TE/TR as 25/500 ms, FOV as 32mm, and matrix size as 64x64. 0.3 ml of Gd-DTPA (Magnevist) was manually injected at the 10 second and flushed with 0.5 ml of saline. Relative CT were then generated by calculating theΔR2* from the scans before contrast agent arriving. The integration of the CT curve from contrast agent arriving to the time the value dropping to half maximum was regarded as first pass CBV, while the integration of last 80 data points (i.e. 40 seconds) was utilized for recirculation CBV. Four pre-MION and four post-MION gradient echo EPI (TE/TE as 25/2500ms) were then scanned with a Fe dosage of 20mg/kg. TheΔR2* maps by the susceptibility of steady state MION were also considered as MION CBV maps and utilized as references for comparison.[2] Results Fig. 1 showed one example of the scatter plot of the first pass CBV and recirculation CBV of one slice of our experiments. The results display considerably positive correlation between the first pass and recirculation CBV map. R squares were found to be 0.8958 ±0.0448, which are consistent with our hypothesis. However, an intercept of regression line was also showed in Fig. 1, which implies the deviation from proportionality within at least one of the methods. Therefore, we applied MION CBV map as a reference to compare with first pass and recirculation CBV maps, and r squares were found to be 0.62193 ±0.15744, 0.69407± 0.1515, respectively (Table 1). For intercept per slope values were found to be 0.072326±0.044215 and 0.033261±0.041996, respectively as well, which represent the normalize offset of the first pass and recirculation CBV maps. The higher r square and lower normalized offset between recirculation CBV and MION CBV once more support the feasibility of recirculation CBV map, since MION CBV map is taken to be as an ideal CBV. Discussion and Conclusion The recirculation CBV map is highly relative to first pass CBV map. Besides, the superior regression curves with MION CBV map guarantee the advantage of using the recirculation CBV for small animal imaging. The errors of first pass CBV may come from the fast changing peak value, relative low scanning speed of MRI, and even the nonlinearity between ΔR2* and contrast agent concentration around peak value. On the contrary, the recirculation CBV seems more reliable by recruiting more data points for calculation, since the extravasation supposed to be minor in the short duration of DSC imaging. In conclusion, we confirmed the feasibility of using the recirculation part of CT for relative CBV measurement. One may also consider integrating the total area under the CT curve including both the first pass and recirculation parts, to further enrich the data points and to enhance the reliability. Reference 1. Axel L, Radiology 137, 679-86. (1980). 2. Mandeville JB et al., MRM 39, 615-24 (1998).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of methods for quantitative analysis of dynamic susceptibility contrast enhanced brain perfusion MRI

Quantitative cerebral blood flow (CBF) can be obtained from dynamic susceptibility contrast (DSC) MRI using for instance the truncated singular value decomposition (tSVD). Block-circulant SVD and reformulated SVD (rSVD) are modified SVD approaches. The purpose of this study is to compare the different approaches. The optimal truncation thresholds (PSVD) for tSVD and block-circulant SVD are dete...

متن کامل

Comparison between intensity normalization techniques for dynamic susceptibility contrast (DSC)-MRI estimates of cerebral blood volume (CBV) in human gliomas.

PURPOSE To compare "standardization," "Gaussian normalization," and "Z-score normalization" intensity transformation techniques in dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) estimates of cerebral blood volume (CBV) in human gliomas. DSC-MRI is a well-established biomarker for CBV in brain tumors; however, DSC-MRI estimates of CBV are semiquantitative. The use of image ...

متن کامل

Alterations of the Blood-Brain Barrier and Regional Perfusion in Tumor Development: MRI Insights from a Rat C6 Glioma Model

OBJECTIVES Angiogenesis and anti-angiogenetic medications play an important role in progression and therapy of glioblastoma. In this context, in vivo characterization of the blood-brain-barrier and tumor vascularization may be important for individual prognosis and therapy optimization. METHODS We analyzed perfusion and capillary permeability of C6-gliomas in rats at different stages of tumor...

متن کامل

Role of FDG‐PET/MRI, FDG‐PET/CT, and Dynamic Susceptibility Contrast Perfusion MRI in Differentiating Radiation Necrosis from Tumor Recurrence in Glioblastomas

BACKGROUND AND PURPOSE To compare the utility of quantitative PET/MRI, dynamic susceptibility contrast (DSC) perfusion MRI (pMRI), and PET/CT in differentiating radiation necrosis (RN) from tumor recurrence (TR) in patients with treated glioblastoma multiforme (GBM). METHODS The study included 24 patients with GBM treated with surgery, radiotherapy, and temozolomide who presented with progres...

متن کامل

Dynamic susceptibility contrast MRI

Introduction Quantitative dynamic susceptibility contrast perfusion MRI (DSC-MRI) is based on the monitoring of the first passage of a bolus of contrast agent through the brain tissue and a brain-feeding artery. The contrast agent is injected rapidly by means of an MRinjector in the antecubital vein in the patients arm and a saline flush is used to push the contrast agent into the direction of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009