Effect of age, sex, and refractive errors on central corneal thickness measured by Oculus Pentacam®

نویسندگان

  • Nauman Hashmani
  • Sharif Hashmani
  • Azfar N Hanfi
  • Misbah Ayub
  • Choudhry M Saad
  • Hina Rajani
  • Marium G Muhammad
  • Misbahul Aziz
چکیده

BACKGROUND Central corneal thickness (CCT) can be used to assess the corneal physiological condition as well as the pathological changes associated with ocular diseases. It has an influence on the measurement of intraocular pressure and is being used as a screening tool for refractive surgery candidates. The aim of this study was to determine the median CCT among normal Pakistani population and to correlate CCT with age, sex, and refractive errors. METHODS We conducted a retrospective analysis of 5,171 healthy eyes in 2,598 patients who came to Hashmanis Hospital, Karachi, Pakistan. The age of the patients ranged from 6 to 70 years. The refractive error was gauged by an auto-refractometer, and CCT was measured using Oculus Pentacam®. RESULTS The median CCT of our study was 541.0 μm with an interquartile range (IQR) of 44.0 μm. The median age was 26.0 years (IQR: 8.0). Median spherical equivalent (SE) of the patients was -4.3 D (IQR: 3.3) with the median sphere value as -4.0 D (IQR: 3.8). Lastly, the median cylinder was -1.0 D (IQR: 1.3). Age has a weak negative correlation with CCT (r=-0.058) and shows statistical significance (P<0.001). Additionally, males had thinner CCT readings than females (P=0.001). The cylinder values, on the other hand, had a significant (P=0.004) and positive correlation (r=0.154). Three values showed no significant correlation: sphere (P=0.100), SE (P=0.782), and the left or right eye (P=0.151). CONCLUSION Among the Pakistani population, CCT was significantly affected by three variables: sex, age, and cylinder. No relationship of CCT was observed with the left or right eye, sphere, and SE.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Central Corneal Thickness Measured through Pentacam, OCTCasia2, and Orbscan IIz in Normal Individuals

Purpose: To compare the central corneal thickness measured through Pentacam, OCTCasia2, and Orbscan IIz in normal individuals. Methods: In this cross sectional comparative study, the researcher investigated the eyes of 70 normal candidates (140 eyes) with the mean age of 31.42 ± 7.70, referring to Dr. Sedaghat eye clinic for refractive surgery. For each person, Central Corneal Thickness (CCT) w...

متن کامل

Central corneal thickness, anterior chamber depth, and pupil diameter measurements using Visante OCT, Orbscan, and Pentacam.

PURPOSE To evaluate the agreement among three different optical methods in measuring anterior chamber depth (ACD), central corneal thickness (CCT), and pupil diameter. METHODS One hundred eyes of 50 healthy patients (25 men, 25 women) were enrolled in the study. Mean patient age was 25 years (range: 21 to 32 years). Exclusion criteria were history of any intraocular or corneal surgery, contac...

متن کامل

Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry.

PURPOSE To assess the intraoperator repeatability and interoperator reproducibility of central corneal thickness measurements by the Pentacam Scheimpflug imaging system (Oculus) and the optical low-coherence reflectometer (OLCR) pachymeter (Haag-Streit) and to compare them with those of ultrasound (US) pachymetry. SETTING Assaf Harofe Medical Center Ophthalmology Outpatient Clinic, Zerifin, I...

متن کامل

Evaluation of Corneal Deformation Analyzed with Scheimpflug Based Device in Healthy Eyes and Diseased Ones

This study was designed to evaluate the correlation between corneal biomechanical and morphological data in healthy eyes, eyes that underwent myopic photorefractive keratectomy (PRK), keratoconus affected eyes, and keratoconus affected eyes that underwent corneal collagen crosslinking (CCC). Complete clinical eye examination of all eyes was followed by tomographic (Pentacam, Oculus, Wetzlar, Ge...

متن کامل

Corneal transparency after cross-linking for keratoconus: 1-year follow-up.

PURPOSE To evaluate the changes in corneal transparency and thickness measured objectively using Pentacam Scheimpflug (Oculus Optikgeräte GmbH) corneal tomography (densitometry) after corneal cross-linking (CXL). METHODS Twenty-two eyes from 15 patients with keratoconus underwent CXL. Corneal thickness and curvature as well as lens and corneal densitometry were measured at baseline and 1, 3, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 11  شماره 

صفحات  -

تاریخ انتشار 2017