Transition into driven equilibrium of the balanced steady-state free precession as an ultrafast multisection T2-weighted imaging of the brain.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Current T2-weighted imaging takes >3 minutes to perform, for which the ultrafast transition into driven equilibrium (TIDE) technique may be potentially helpful. This study qualitatively and quantitatively evaluates the imaging of transition into driven equilibrium of the balanced steady-state free precession (TIDE) compared with TSE and turbo gradient spin-echo on T2-weighted MR images. MATERIALS AND METHODS Thirty healthy volunteers were examined with T2-weighted images by using TIDE, TSE, and turbo gradient spin-echo sequences. Imaging was evaluated qualitatively by 2 independent observers on the basis of a 4-point rating scale regarding contrast characteristics and artifacts behavior. Image SNR and contrast-to-noise ratio were quantitatively assessed. RESULTS TIDE provided T2-weighted contrast similar to that in TSE and turbo gradient spin-echo with only one-eighth of the scan time. TIDE showed gray-white matter differentiation and iron-load sensitivity inferior that of TSE and turbo gradient spin-echo, but with improved motion artifacts reduction on qualitative scores. Nonmotion ghosting artifacts were uniquely found in TIDE images. The overall SNRs of TSE were 1.9-2.0 times those of turbo gradient spin-echo and 1.7-2.2 times of those of TIDE for brain tissue (P < .0001). TIDE had a higher contrast-to-noise ratio than TSE (P = .169) and turbo gradient spin-echo (P < .0001) regarding non-iron-containing gray matter versus white matter. TIDE had a lower contrast-to-noise ratio than turbo gradient spin-echo and TSE (P < .0001) between iron-containing gray matter and white matter. CONCLUSIONS TIDE provides T2-weighted images with reduced scan times and reduced motion artifacts compared with TSE and turbo gradient spin-echo with the trade-off of reduced SNR and poorer gray-white matter differentiation.
منابع مشابه
Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm
Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...
متن کاملUltrahigh-resolution imaging of the human brain with phase-cycled balanced steady-state free precession at 7 T.
OBJECTIVES The objectives of this study were to acquire ultra-high resolution images of the brain using balanced steady-state free precession (bSSFP) at 7 T and to identify the potential utility of this sequence. MATERIALS AND METHODS Eight volunteers participated in this study after providing informed consent. Each volunteer was scanned with 8 phase cycles of bSSFP at 0.4-mm isotropic resolu...
متن کاملBreast MRI Using a Balanced Steady-State Free Precession Imaging with a Two-Point Dixon Fat-Water Reconstruction Algorithm: Preliminary Experience and Comparison with 2D FSE
INTRODUCTION: Balanced steady-state free precession (b-SSFP) techniques yielding high SNR images in short scan times with T2-like image contrast have several appealing attributes for clinical breast MRI [1]. Clinical T2 imaging in the breast is routinely performed using a fat suppressed 2D Fast Spin Echo (FSE) pulse sequence with high in-plane spatial resolution. The 3-5 mm slice thickness obsc...
متن کاملUltrafast near-isotropic spatial resolution 3D balanced-SSFP Dixon imaging in the breast
INTRODUCTION: T2 imaging in the breast is most commonly performed using a fat suppressed 2D Fast Spin Echo (FSE) pulse sequence. The in-plane spatial resolution is high (<1mm) but the 3-4 mm slice thickness blurs fine structures and makes multi-planar reformatting sub-optimal. Balanced steady-state free precession (b-SSFP) techniques yield high SNR images in short scan times with a T2-like (T2/...
متن کاملSpoiled & Balanced Gradient Echo Methods
Imaging with spoiled, balanced or nonbalanced gradient echo (GRE) refers to a class of fast imaging sequences that use a dynamic equilibrium or steady state signal for imaging. As originally introduced in 1958 by Carr (1) for NMR spectroscopy, a dynamic equilibrium or steadystate can be established by a train of radio-frequency (RF) excitation pulses interleaved by periods of ‘free precession’,...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 35 6 شماره
صفحات -
تاریخ انتشار 2014