An innovative simplified method for assessing available bone in mandible for implant

نویسندگان

  • S. Binsu
  • K. Chandrasekharan Nair
  • Sanjana Nayar
  • Suchita Tella
چکیده

The primary factor that determines the success of implant is the amount of available bone in the edentulous site. Diagnostic imaging and techniques help to develop and implement a cohesive and comprehensive treatment plan according to the available bone. In the following case report an innovative simplified method (poor man CT) is used to fabricate a three dimensional model to assess the available bone for implant placement in mandible.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه بیومکانیکی ایمپلنت دندانی تیتانیوم خالص با زیرکونیوم -5/2% نایوبیوم پس از کاشت به روش اجزای محدود

Background and Aims: Improving dental implantation conditions in order to reduce the failure is always desirable for researchers. The aim of this study was to compare two different materials of dental implants from the viewpoint of biomechanical effect after placement and loading in the mandible. Materials and Methods: A 3D model of mandible was designed in the MIMICS 10.01 software. Then,...

متن کامل

Step-wise analysis of the dental implant insertion process using the finite element technique.

OBJECTIVES Using the finite element method (FEM), the insertion process of a dental implant into a section of the human mandible is analysed. The ultimate aim of this article is to advance the use of an innovative engineering approach in dental practices, especially in the process of dental implantation. MATERIAL AND METHODS The FEM and analysis techniques are used to replicate and evaluate t...

متن کامل

تعیین توزیع تنش و کرنش استخوان اطراف ایمپلنت در طرح All-on-4 به روش آنالیز اجزای محدود

Background and Aims: The All-on-4 design with its significant advantages is an appropriate model in reconstruction of edentulous mandible. Evaluation of stress and strain distribution in this model is necessary for better judgment. The purpose of this FEA study was to measure stress and strain distribution on peri-implant bone in All-on-4 design in edentulous mandible. Materials and Methods: Th...

متن کامل

بررسی اثر ضخامت پوشش هیدروکسی آپاتیت بر توزیع تنش در اطراف سطح تماس ایمپلنت دندانی- استخوان با روش المان محدود

  Background and Aims: Hydroxyapatite coating has allocated a special place in dentistry due to its biocompatibility and bioactivity. The purpose of this study was to evaluate the relation between the hydroxyapatite thickness and stress distribution by using finite element method.   Materials and Methods: In this paper, the effect of hydroxyapatite coating thickness on dental implants was studi...

متن کامل

Interradicular Space in the Anterior Mandible on CBCT Scans of an Iranian Population

Abstract Background and Aim: This study aimed to assess the bone thickness at the interradicular spaces in the anterior mandible on cone-beam computed tomography (CBCT) scans of patients to find appropriate sites for mini-implant and miniscrew placement. Materials and Methods: This analytical cross-sectional study was conducted on 161 CBCT scans of patients (98 females and 63 male...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016