Isocenter Verification in Radiotherapy Clinical Practice Using Virtual Simulation: An Image Registration Approach
نویسندگان
چکیده
This chapter presents an overview of the procedures that are used for the verification of the patient position during radiotherapy. Furthermore, a method for the verification of the radiotherapy isocenter prior to treatment delivery is proposed. The method is based on the alignment of two Computed Tomography (CT) scans: a scan, which is acquired for treatment planning, and an additional verification scan, which is acquired prior to the treatment delivery. The proposed method was applied to CT scans, acquired from 20 patients with abdominal tumors and 20 patients with breast/lung cancer. The results of the proposed method were compared with the ones obtained using conventional methods, indicating that the estimated isocenter displacement can be translated into patient setup error inside the treatment room. George Matsopoulos National Technical University of Athens, Greece Pantelis A. Asvestas Technological Educational Institute of Athens, Greece Vasiliki Markaki National Technical University of Athens, Greece Kalliopi Platoni University of Athens, Greece Vasilios Kouloulias University of Athens, Greece
منابع مشابه
Pretreatment quality control of single isocenter half- beam treatment planning technique using an amorphous silicon electronic portal-imaging device (EPID)
Introduction: Electronic portal imaging devices (EPIDs) are fundamentally used for instantaneous verification of the patient set‐up, block shape, and leaf positions during radiation therapy. In radiotherapy, situations arise in which an inclined PTV must be treated mutually with adjacent nodal regions. This methodology is most widely used for matching tangential/lateral breas...
متن کاملAutomated Verification of IGRT‐based Patient Positioning
A system for automated quality assurance in radiotherapy of a therapist's registration was designed and tested in clinical practice. The approach compliments the clinical software's automated registration in terms of algorithm configuration and performance, and constitutes a practical approach for ensuring safe patient setups. Per our convergence analysis, evolutionary algorithms perform better...
متن کاملCalculation of Inter- and Intra-Fraction Motion Errors at External Radiotherapy Using a Markerless Strategy Based on Image Registration Combined with Correlation Model
Introduction: A new method based on image registration technique and an intelligent correlation model to calculate. The present study aimed to propose inter- and intra-fraction motion errors in order to address the limitations of conventional Patient positioning methods. Material and Methods: The configuration of the markerless method wa...
متن کاملAutomatic 2D/2D Registration using Multiresolution Pyramid based Mutual Information in Image Guided Radiation Therapy
Medical image registration is the key technology in image guided radiation therapy (IGRT) systems. On the basis of the previous work on our IGRT prototype with a biorthogonal x-ray imaging system, we described a method focused on the 2D/2D rigid-body registration using multiresolution pyramid based mutual information in this paper. Three key steps were involved in the method : firstly, four 2D ...
متن کاملA simple technique for craniospinal radiotherapy in the supine position.
PURPOSE Craniospinal irradiation poses technical difficulties that may be addressed with the use of the newer technologies that have become available over the past decade. The use of CT simulation allows improved target localisation and beam geometry definition while significantly reducing the treatment simulation time. We have developed a CT-based technique for whole CNS irradiation in the sup...