Panoramic Views of the Cygnus Loop

نویسندگان

  • James R. Graham
  • Matthew J. Richter
چکیده

We present a complete atlas of the Cygnus Loop supernova remnant in the light of [O III] (λ5007), Hα, and [S II] (λλ6717, 6731). We include low-resolution (25) global maps and smaller fields at 6 resolution from observations using the Prime Focus Corrector on the 0.8-m telescope at McDonald Observatory. Despite its shell-like appearance, the Cygnus Loop is not a current example of a Sedov-Taylor blast wave. Rather, the optical emission traces interactions of the supernova blast wave with clumps of gas. The surrounding interstellar medium forms the walls of a cavity through which the blast wave now propagates, including a nearly complete shell in which non-radiative filaments are detected. We identify non-radiative shocks around half the perimeter of the Cygnus Loop, and they trace a circle of radius R = 1. 4 (19 pc) in the spherical cavity walls. The Cygnus Loop blast wave is not breaking out of a dense cloud, but is instead running into confining walls. Modification of the shock velocity and gas temperature due to interaction of the blast wave with the surrounding medium introduces errors in estimates of the age of this supernova remnant. The optical emission of radiative shocks arises only where the blast wave encounters inhomogeneities in the ambient medium; it is not a consequence of gradual evolution to a global radiative phase. Distance measurements that rely on this uniform blast wave evolution are uncertain, but the radiative shocks can be used Guest Observer, McDonald Observatory, University of Texas at Austin

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ROSAT all-sky survey map of the Cygnus Loop: Overall structure and comparison with radio map

The Cygnus Loop is one of the largest and nearest supernova remnants. It was observed by the PSPC detector of the Röntgen-Satellite ROSAT during the survey phase of the ROSAT mission. This has resulted in the highest–sensitivity complete x-ray image of the Cygnus Loop. It also has the high spatial resolution of one arcmin and contains spectral information. It is thus the best map of the Cygnus ...

متن کامل

تعیین ضرایب تصحیح تصاویر در تکنیک پانورامیک با استفاده از فانتوم فک پایین

Background and Aim: Image distortion is one of the major problems in panoramic radiography. Horizontal and vertical correction factors could be determined for more efficient clinical applications. The purpose of this study was to determine horizontal and vertical correction factors in panoramic radiography.Materials and Methods: In this test evaluation study in which an asymetric mandibular pha...

متن کامل

New λ 6 cm observations of the Cygnus Loop

Radio continuum and polarization observations of the entire Cygnus Loop at λ6 cm wavelength were made with the Urumqi 25 m telescope. The λ6 cm map is analysed together with recently published maps from the Effelsberg 100 m telescope at λ21 cm and λ11 cm. The integrated flux density of the Cygnus Loop at λ6 cm is 90±9 Jy, which implies a spectral index of α = −0.40 ± 0.06 being consistent with ...

متن کامل

Appearance of Anatomical Structures of Mandible on Panoramic Radiographs (Panorex-X-Ray) in Patients who Referred to Dental School of Shahid Beheshti University

Purpose: Currently panoramic radiography is used for diagnostic dental, and bone lesions, but anatomical structures also can see, for example incisive canal. At present time incisive canal position is investigated in Iranian population. Materials and Methods: Panoramic radiographs were taken by Planmeca machine from 412 patients using standard exposure. The position of patient was in compliance...

متن کامل

Agreement of Bitewing and Digital Panoramic Radiographies in the Detection of Proximal Caries

Background & Aims: Conventional radiography is used for the diagnosis of problems such as dental caries and failure in root canal therapy. The diagnosis accuracy of conventional radiography is acceptable in the evaluation of anatomical and pathological structures. However, it seems that by using digital radiography we can obtain more information in this field. The aim of this study is to compar...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998