A Polylactide Bioresorbable Scaffold Eluting Everolimus for Treatment of Coronary Stenosis: 5-Year Follow-Up.

نویسندگان

  • Patrick W Serruys
  • John Ormiston
  • Robert-Jan van Geuns
  • Bernard de Bruyne
  • Dariusz Dudek
  • Evald Christiansen
  • Bernard Chevalier
  • Pieter Smits
  • Dougal McClean
  • Jacques Koolen
  • Stephan Windecker
  • Robert Whitbourn
  • Ian Meredith
  • Luc Wasungu
  • Divine Ediebah
  • Susan Veldhof
  • Yoshinobu Onuma
چکیده

BACKGROUND Long-term benefits of coronary stenosis treatment with an everolimus-eluting bioresorbable scaffold are unknown. OBJECTIVES This study sought to evaluate clinical and imaging outcomes 5 years after bioresorbable scaffold implantation. METHODS In the ABSORB multicenter, single-arm trial, 45 (B1) and 56 patients (B2) underwent coronary angiography, intravascular ultrasound (IVUS), and optical coherence tomography (OCT) at different times. At 5 years, 53 patients without target lesion revascularization underwent final imaging. RESULTS Between 6 months/1 year and 5 years, angiographic luminal late loss remained unchanged (B1: 0.14 ± 19 mm vs. 0.13 ± 0.33 mm; p = 0.7953; B2: 0.23 ± 0.28 mm vs. 0.18 ± 0.32 mm; p = 0.5685). When patients with a target lesion revascularization were included, luminal late loss was 0.15 ± 0.20 mm versus 0.15 ± 0.24 mm (p = 0.8275) for B1 and 0.30 ± 0.37 mm versus 0.32 ± 0.48 mm (p = 0.8204) for B2. At 5 years, in-scaffold and -segment binary restenosis was 7.8% (5 of 64) and 12.5% (8 of 64). On IVUS, the minimum lumen area of B1 decreased from 5.23 ± 0.97 mm(2) at 6 months to 4.89 ± 1.81 mm(2) at 5 years (p = 0.04), but remained unchanged in B2 (4.95 ± 0.91 mm(2) at 1 year to 4.84 ± 1.28 mm(2) at 5 years; p = 0.5). At 5 years, struts were no longer discernable by OCT and IVUS. On OCT, the minimum lumen area in B1 decreased from 4.51 ± 1.28 mm(2) at 6 months to 3.65 ± 1.39 mm(2) at 5 years (p = 0.01), but remained unchanged in B2, 4.35 ± 1.09 mm(2) at 1 year and 4.12 ± 1.38 mm(2) at 5 years (p = 0.24). Overall, the 5-year major adverse cardiac event rate was 11.0%, without any scaffold thrombosis. CONCLUSIONS At 5 years, bioresorbable scaffold implantation in a simple stenotic lesion resulted in stable lumen dimensions and low restenosis and major adverse cardiac event rates. (ABSORB Clinical Investigation, Cohort B [ABSORB B]; NCT00856856).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Economic Outcomes of Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Stents in Patients Undergoing Percutaneous Coronary Intervention: 1-Year Results From the ABSORB III Trial.

OBJECTIVES The purpose of this study was to evaluate the economic impact of the Absorb bioresorbable vascular scaffold compared with the Xience everolimus-eluting stent in patients undergoing percutaneous coronary intervention. BACKGROUND The ABSORB III trial (Everolimus-Eluting Bioresorbable Scaffolds for Coronary Artery Disease) demonstrated that the Absorb scaffold was noninferior to the X...

متن کامل

Evaluation of the second generation of a bioresorbable everolimus drug-eluting vascular scaffold for treatment of de novo coronary artery stenosis: six-month clinical and imaging outcomes.

BACKGROUND The first generation of the bioresorbable everolimus drug-eluting vascular scaffold showed signs of shrinkage at 6 months, which largely contributed to late luminal loss. Nevertheless, late luminal loss was less than that observed with bare metal stents. To maintain the mechanical integrity of the device up to 6 months, the scaffold design and manufacturing process of its polymer wer...

متن کامل

1-year follow-up optical coherence tomography of a "hybrid" neocarina after T-stenting with small protrusion technique using a bioresorbable vascular scaffold and a metallic stent.

A 75-year-old man with stable angina underwent coronary angiography demonstrating significant stenosis at the bifurcation of the left anterior descending coronary artery (LAD) with a diagonal branch (Figure 1A). Following predilation, a 3.5 28-mm bioresorbable vascular scaffold (BVS) (Absorb, Abbott Vascular, Santa Clara, California) was implanted in the LAD. This was followed by post-dilation ...

متن کامل

Five-year optical coherence tomography follow-up of an everolimus-eluting bioresorbable vascular scaffold: changing the paradigm of coronary stenting?

A 58-year-old man, included in cohort A of the Bioabsorbable Vascular Solutions First in Man Clinical Investigation: A Clinical Evaluation of the Bioabsorbable Vascular Solutions Everolimus Eluting Coronary Stent System in the Treatment of Patients With Single de Novo Native Coronary Artery Lesions (ABSORB) trial,1 had undergone implantation of a bioresorbable everolimus-eluting scaffold (BVS; ...

متن کامل

Long-Term Efficacy and Safety of Everolimus-Eluting Bioresorbable Vascular Scaffolds Versus Everolimus-Eluting Metallic Stents

Second-generation metallic drug-eluting stents (DES) have been widely recommended for percutaneous coronary intervention. One of the main drawbacks of these devices is the risk of late adverse events (ie, beyond 1 year), particularly repeat revascularization, which are partly related to the persistence of the metallic stents in the coronary artery wall. In this context, the bioresorbable vascul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 67 7  شماره 

صفحات  -

تاریخ انتشار 2016