Duplex sonography in embolotherapy of external carotid artery traumatic aneurysms.

نویسندگان

  • V L Giyanani
  • A J Gerlock
  • M Mirfakhraee
  • D Lew
  • R C Bryarly
چکیده

Until recently, arteriography has been the method of choice for diagnosing traumatic aneurysms and for follow-up after transcatheter coil embolization [1-3]. Duplex sonography can now playa complementary role in the diagnosis and followup of these lesions. Serial duplex sonographic examinations provide a noninvasive method of monitoring the cessation of flow within the aneurysms and their resolution. This report describes how duplex scanning was used in two patients to make the diagnosis of traumatic aneurysms and to observe their progress after embolization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Power transcranial Doppler ultrasound in the detection of intracranial aneurysms.

BACKGROUND AND PURPOSE We sought to perform a large, prospective, multicenter, blinded study comparing power transcranial color duplex sonography (power TCDS) with intra-arterial digital subtraction angiography (IADSA) in the detection of intracranial aneurysms. METHODS Contemporaneous TCDS and IADSA examinations were performed in 171 subjects with suspected intracranial aneurysm. Via the tem...

متن کامل

Evaluation of revascularization after total arch replacement in common carotid artery occlusion

Occlusion of the common carotid artery (CCA) is rare. CCA occlusion (CCAO) can present as drowsiness and right hemiplegia related to emboli after total arch replacement. Although we selected a follow-up at first because color duplex sonography showed retrograde flow from the left external carotid artery to the internal carotid artery, this patient had epilepsy and single-photon emission compute...

متن کامل

Cardiac-gated local coil MR imaging of the carotid neck bifurcation.

The value of duplex Doppler sonography as a noninvasive technique for evaluating the carotid neck vessels has been well documented [1-4]. The sensitivity and specificity of duplex Doppler sonography in the detection of high-grade stenosis (greater than 80%) approximates 90% [1] . However, duplex Doppler sonography has several limitations. Plaque ulceration cannot be detected reliably, even with...

متن کامل

Duplex Doppler sonography of the carotid artery: false-positive results in an artery contralateral to an artery with marked stenosis.

Anecdotal reports have described a false-positive "jet effect" or velocity increase in the carotid artery contralateral to an artery with significant stenosis or occlusion when using duplex Doppler sonography. In this study, the frequency, significance, and possible reasons for this finding were evaluated by a retrospective comparison of duplex sonography and angiography. Twenty-three patients ...

متن کامل

Preoperative evaluation of carotid artery stenosis: comparison of contrast-enhanced MR angiography and duplex sonography with digital subtraction angiography.

BACKGROUND AND PURPOSE Contrast-enhanced MR angiography and extracranial color-coded duplex sonography are noninvasive, preoperative imaging modalities for evaluation of carotid artery stenosis. Innovative techniques and improvements in image quality require frequent reassessment of accuracy, reliability, and diagnostic value compared with those of digital subtraction angiography (DSA). We eval...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 8 6  شماره 

صفحات  -