The Use of a Ti-Ni Shape Memory Alloy Ring Bone Fixator During the Retrograde Nailing of Supracondylar Femoral Fractures

نویسندگان

  • Hyuk-Soo Han
  • Dae-Ha Kim
  • Seung-Baik Kang
چکیده

PURPOSE To identify the effects of using a Ti-Ni shape memory alloy ring shaped bone fixator (SMA-rBF) during the retrograde nailing of supracondylar femoral fractures. MATERIALS AND METHODS The authors reviewed 25 patients with a supracondylar femoral fracture treated by retrograde intramedullary nailing with or without SMA-rBF (group S, 12/25; group N, 13/25). Radiological measurements of angular deformity were performed and functional assessments were made using the Sanders grading system. RESULTS All fractures healed after an average of 12.2 weeks (range, 9-15 weeks) in group N and after 11.6 weeks (range, 10-13 weeks) in group S (p=0.351). The mean angle of coronal angular deformity was valgus 0.8° (range, varus 2.3°-valgus 4.5°) in group N and valgus 0.7° (range, varus 1.0°-valgus 2.4°) in group S (p=0.892). The mean angle of sagittal angular deformity was 1.0° in extension (range, flexion 3.2°-extension 3.1°) in group N and 0° (range, flexion 2.1°-extension 1.2°) in group S (p=0.022). However, functional grading evaluations revealed no differences between the two groups. CONCLUSIONS When reduction of a distal femoral fracture with retrograde nailing was difficult additional mini-open reduction and fixation with a ring shaped SMA did not delay or prevent bony union and resulted in good postoperative alignment.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retrograde Intramedullary Nailing for Periprosthetic Supracondylar Fractures of the Femur after Total Knee Arthroplasty

BACKGROUND Periprosthetic supracondylar fractures of the femur after total knee arthroplasty are not common but are usually difficult to treat due to the advanced age of patients and frequently accompanying osteoporosis. Retrograde intramedullary nailing can be effective in promoting healing of these fractures by providing sufficient stability, but the number of beneficiaries is small due to it...

متن کامل

Fabrication of Spiral Stent with Superelastic/ Shape Memory Nitinol Alloy for Femoral Vessel

Stent is a metal mesh tube for opening the obstructed vessels of the body. Ni-Ti alloy is a suitable metal for fabrication of stent due to its potential for applying the appropriate stress and strain to the vessel walls. In this study, super-elastic Nitinol wire was used to build stent samples usable to open femoral vessel. Ageing was performed at 500°C for different periods of time to determin...

متن کامل

Application of Ni-Ti Alloy connector for the treatment of comminuted coronal plane supracondylar-condylar femoral fractures: a retrospective review of 21 patients

BACKGROUND Our preliminary retrospective study assessed outcomes after the use of Ni-Ti arched shape-memory connector (ASC) combined with partially threaded cancellous screws (PTCS) to repair coronal plane supracondylar-condylar femoral fractures. METHODS Twenty-one patients (16 men and 5 women) with a mean age of 34.1 years (range, 28 to 44 years) with coronal plane supracondylar and condyla...

متن کامل

Retrograde Intramedullary Nailing for Distal Femur Fracture with Osteoporosis

BACKGROUND The incidence of distal femur fracture in the elderly has been increasing recently, and commonly occurs with osteoporosis. Retrograde intramedullary nailing has been considered a good surgical option for distal femur fracture. The purpose of the present study was to present our surgical results with retrograde intramedullary nailing for distal femur fractures with osteoporosis. MET...

متن کامل

Retrograde locked intramedullary nailing for aseptic supracondylar femoral nonunion following failed locked plating.

PURPOSE To review the outcome of retrograde locked nailing for aseptic supracondylar femoral nonunions following failed locked plating. METHODS Records of 20 men and 4 women aged 20 to 57 (mean, 39) years who underwent retrograde locked intramedullary nailing for aseptic supracondylar femoral nonunion following failed locked plating were reviewed. There were 20 closed and 4 open Gustilo type ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 23  شماره 

صفحات  -

تاریخ انتشار 2011