The Sandwich spectrometer for ultra low-level gamma-ray spectrometry.

نویسندگان

  • J S Elisabeth Wieslander
  • Mikael Hult
  • Joël Gasparro
  • Gerd Marissens
  • Marcin Misiaszek
  • Werner Preusse
چکیده

The technical details and performance of the newly developed Sandwich spectrometer for ultra low-level gamma-ray spectrometry are presented. The spectrometer, which consists of two HPGe detectors, an active muon shield and a lead/copper shield with a convenient and rapid opening mechanism, is located in an underground laboratory at a depth of 500 m water equivalent. The data is collected in list mode, which enables off-line data analysis to identify muon-induced events and possible Ge detector crosstalk due to Compton scattering. The background count-rate from 40 to 2700 keV normalised to the mass of the Ge crystals is 220 day(-1)kg(-1).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization of measurement counting time in Gamma-ray spectrometry of soil samples

The method of optimal measurement counting time in Gamma spectrometry for soil samples was studied. Gamma spectrometry was done based on minimum detectable activity using the HPGe- p type with efficiency of 30% and FWHM 1.7keV (for 1.33 MeV 60Co). The samples were IAEA-RG Th-1, IAEA-RGU-1 and IAEA-RGK-1 prepared in bottles. The measurements were done for 12 different counting times from 5 min t...

متن کامل

Measurement of Radioactivity Levels and Health Risks in the Surrounding Soil of Shazand Refinery Complex in Arak, Iran, Using Gamma-Ray Spectrometry Method

ntroduction: The purpose of this study was to measure the radioactivity in the agricultural soil of south-east of Shazand Refinery Complex to determine both reliable baseline data on the radiation level and the radiation dose exposure to the farmers and inhabitants of the studied area. Material and Methods: This study was conducted on 21 soil...

متن کامل

A Comparative Study of Field Gamma-ray Spectrometry by NaI(Tl) and HPGe Detectors in the South Caspian Region

Natural radionuclides present in soil as well as certain anthropogenic radionuclides released to the environment are the major contributors to terrestrial outdoor exposures. In the assessment of human exposures from environmental radioactivity, besides the conventional method of soil and vegetation sampling combined with laboratory based analyses of environmental media, the other choice would b...

متن کامل

Transition from analogue-to-digital nuclear electronics for precise gamma radiation spectroscopy: advantages and limitations

In this paper, digital signal processing for precise gamma ray spectroscopy is presented. The basis of this system is a 14bit waveform digitizer which samples the output of pre-amplifier signals directly. The advantages and limitations of the digital spectrometer compared with analog spectrometer has been tested and analyzed from precise gamma ray spectroscopy point of view. The results shows t...

متن کامل

Gamma-ray spectrometry of ultra low levels of radioactivity within the material screening program for the GERDA experiment.

In present and future experiments in the field of rare events physics a background index of 10(-3) counts/(keV kg a) or better in the region of interest is envisaged. A thorough material screening is mandatory in order to achieve this goal. The results of a systematic study of radioactive trace impurities in selected materials using ultra low-level gamma-ray spectrometry in the framework of the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine

دوره 67 5  شماره 

صفحات  -

تاریخ انتشار 2009