Fire sprinkler systems and the use of CPVC plastic piping

ثبت نشده
چکیده

In the 1980s, a special compound formula was developed to suit the demands of a fire sprinkler system for life safety applications. In 1984, the first BlazeMaster® CPVC fire sprinkler systems were deployed in the United States. Since then, BlazeMaster fire sprinkler systems have been performing so successfully that 50% of all NFPA 13 applications in the US are specified with BlazeMaster pipes and fittings.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of factors affecting the accumulation of vinyl chloride in polyvinyl chloride piping used in drinking water distribution systems.

Plastic piping made of polyvinyl chloride (PVC), and chlorinated PVC (CPVC), is being increasingly used for drinking water distribution lines. Given the formulation of the material from vinyl chloride (VC), there has been concern that the VC (a confirmed human carcinogen) can leach from the plastic piping into drinking water. PVC/CPVC pipe reactors in the laboratory and tap samples collected fr...

متن کامل

Piping Fragility Composed of Different Materials by Using OpenSees Software

A failure of the non-structural component can cause significant damages in critical facilities such as nuclear power plants and hospitals. Historically, it was reported that the damage from the leakage of sprinkler systems, resulted in the shutdown of hospitals for several weeks by the 1971 San Fernando and 1994 North Ridge earthquakes. In most cases, water leakages were observed at the cross j...

متن کامل

Investigation of Sprinkler Sprays on Fire Induced Doorway Flows

Performance based methodologies are becoming increasingly common in fire safety due to the inability of prescriptive codes to account for every architectural feature. Fire Sprinkler suppression systems have long been used to provide property protection and enhance life safety. However, very few methodologies exist to account for the impact of sprinkler sprays on fire scenarios. Current methods ...

متن کامل

Bayes Networks and Fault Tree Analysis Application in Reliability Estimation (Case Study: Automatic Water Sprinkler System)

In this study, the application of Bayes networks and fault tree analysis in reliability estimation have been investigated. Fault tree analysis is one of the most widely used methods for estimating reliability. In recent years, a method called "Bayes Network" has been used, which is a dynamic method, and information about the probable failure of the system components will be updated according to...

متن کامل

Experimental Evaluation of the Seismic Performance of Hospital Sprinkler Systems

This paper discusses the experimental set-up and procedures for the seismic testing and evaluation of a sprinkler system in hospital model. Concrete compression tests are ran to ensure compliance with ACI 355.2 anchor testing qualifications. Maximum shear strength of the anchor is found to include within the piping system model. Frame and piping system within the model is tested under input mot...