Diffusion tensor imaging of the normal pediatric spinal cord using an inner field of view echo-planar imaging sequence.
نویسندگان
چکیده
BACKGROUND AND PURPOSE DTI in the brain has been well established, but its application in the spinal cord, especially in pediatrics, poses several challenges. The small cord size has inherent low SNR of the diffusion signal intensity, respiratory and cardiac movements induce artifacts, and EPI sequences used for obtaining diffusion indices cause eddy-current distortions. The purpose of this study was to 1) evaluate the accuracy of cervical spinal cord DTI in children using a newly developed iFOV sequence with spatially selective 2D-RF excitations, and 2) examine reproducibility of the DTI measures. MATERIALS AND METHODS Twenty-five typically developing subjects were imaged twice using a 3T scanner. Axial DTI images of the cervical spinal cord were acquired with this sequence. After motion correction, DTI indices were calculated using regions of interest manually drawn at every axial section location along the cervical spinal cord for both acquisitions. Various DTI indices were calculated: FA, AD, RD, MD, RA, and VR. Geometric diffusion measures were also calculated: Cp, Cl, and Cs. RESULTS The following average values for each index were obtained: FA = 0.50 ± 0.11; AD = 0.97 ± 0.20 × 10(-3)mm(2)/s; RD = 0.41 ± 0.13 × 10(-3)mm(2)/s; MD = 0.59 ± 0.15 × 10(-3)mm(2)/s; RA = 0.35 ± 0.08; VR = 0.03 ± 0.00; Cp = 0.13 ± 0.07; Cl = 0.29 ± 0.09; and Cs = 0.58 ± 0.11. The reproducibility tests showed moderate to strong ICC in all subjects for all DTI parameters (ICC>0.72). CONCLUSIONS This study showed that accurate and reproducible DTI parameters can be estimated in the pediatric cervical spinal cord using an iFOV EPI sequence.
منابع مشابه
Spatially selective 2D RF inner field of view (iFOV) diffusion kurtosis imaging (DKI) of the pediatric spinal cord
Magnetic resonance based diffusion imaging has been gaining more utility and clinical relevance over the past decade. Using conventional echo planar techniques, it is possible to acquire and characterize water diffusion within the central nervous system (CNS); namely in the form of Diffusion Weighted Imaging (DWI) and Diffusion Tensor Imaging (DTI). While each modality provides valuable clinica...
متن کاملIn vivo diffusion tensor imaging of rat spinal cord with echo planar imaging.
The in vivo apparent diffusion tensor (ADT) of spinal cord was measured in nine rats at 2.0 T using an interleaved multi-shot echo planar imaging (EPI) diffusion sequence. A technique that combines sliding acquisition and phase correction, based on a calibration scan, to reduce ghosting artifacts in the images introduced by the strong diffusion-sensitizing gradients was described. Two rotationa...
متن کاملDistortion correction in spinal cord DTI: What’s the best approach?
Introduction Susceptibility artifacts induced by B0-field inhomogeneities are common issue in echo planar imaging (EPI). They are particularly problematic in the spinal cord region, inducing large geometric and intensity distortions [1]. Although non-EPI techniques could be used instead [2], ultra fast imaging is sometimes a requirement in protocols such as in high angular resolution diffusion ...
متن کاملDiffusion tensor MR imaging in chronic spinal cord injury.
BACKGROUND AND PURPOSE Diffusion tensor MR imaging is emerging as an important tool for displaying anatomic changes in the brain after injury or disease but has been less widely applied to disorders of the spinal cord. The aim of this study was to characterize the diffusion properties of the entire human spinal cord in vivo during the chronic stages of spinal cord injury (SCI). These data provi...
متن کاملReproducible evaluation of spinal cord DTI using an optimized inner volume sequence in combination with probabilistic ROI analysis.
The purpose of this work was to reliably acquire and evaluate diffusion tensor data of the cervical spine. Thereto, we describe an optimized, time-efficient inner-volume echo planar imaging sequence. Multislice capability is achieved by restoring the magnetization in neighbouring slices early during the twice refocused diffusion preparation. The acquired diffusion images showed compelling image...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 33 6 شماره
صفحات -
تاریخ انتشار 2012