Study on Discontinuity Properties of Phased-Array Ultrasound Transducer Affecting to Sound Pressure Fields Pattern
نویسندگان
چکیده
The phased-array ultrasound transducer types are utilities for medical ultrasonography as well as optical imaging. However, their discontinuity characteristic limits the applications due to the artifacts contaminated into the reconstructed images. Because of the effects of the ultrasound pressure field pattern to the echo ultrasonic waves as well as the optical modulated signal, the side lobes of the focused ultrasound beam induced by discontinuity of the phased-array ultrasound transducer might the reason of the artifacts. In this paper, a simple method in approach of numerical simulation was used to investigate the limitation of discontinuity of the elements in phased-array ultrasound transducer and their effects to the ultrasound pressure field. Take into account the change of ultrasound pressure field patterns in the conditions of variation of the pitches between elements of the phased-array ultrasound transducer, the appropriated parameters for phased-array ultrasound transducer design were asserted quantitatively. Keywords—Phased-array ultrasound transducer, sound pressure pattern, discontinuous sound field, numerical visualization.
منابع مشابه
Second Harmonic Field Generation from a Phased Array Transducer and Its Beam Optimization
In this paper, we have done the simulation of ultrasonic field propagation in human tissue medium from a phased array transducer. The ultrasound plane wave propagation has been modeled using the B/A model and has been solved using the time domain based pseudospectral method. The generation of second harmonic field has been studied along the on-axis and off-axis as well and has been compared wit...
متن کاملDesign of Focused Ultrasound Array for Non-Invasive Transesophageal Cardiac Ablation
Atrial fibrillation (AF) is the most common type of arrhythmia, affecting more than 2.2 million Americans. One effective treatment is cardiac ablation, which shows a high rate of success in treating paroxysmal AF. As a prevailing modality for this treatment, catheter ablation using radiofrequency has been effective, but comes with measurable morbidity and significant costs and time associated w...
متن کاملBiplane Phased Array for Ultrasonic Medical Imaging
We report a transducer structure tha t combines two orthogonal phased arrays which enable the real-time scanning of two orthogonal sectors. This biplane phased array is formed by partially dicing the opposite faces of a composite piezoelectric plate in orthogonal directions. Individual elements of the orthogonal arrays show broad radiation patterns close to the theoretical expectations for isol...
متن کاملMathematical Modeling of Ultrasonic Phased Array for Obstacle Location for Visually Impaired
Ultrasonic beam steering characteristics of phased array transducer is mathematically modeled to detect and locate the obstacle for the visually impaired. The main purpose of Beam steering is to steer the beam at a given angle to investigate the object along the beam direction. The effects of various transducer parameters on beam steering properties are studied and optimal phased array is simul...
متن کاملParameter Optimization of Linear Phased Array Transducer for Defect Detection
An optimization design method was proposed for linear phased array ultrasonic imaging testing. In the method, main lobe width and the amplitude ratio of side lobe to main lobe were served as optimization objectives to judge the testing precision of phased array beam directivity. The combination of element of width and inter-element space was served as optimize parameter for the optimization obj...
متن کامل