Intravascular frequency-domain optical coherence tomography assessment of atherosclerosis and stent-vessel interactions in human carotid arteries.

نویسندگان

  • M R Jones
  • G F Attizzani
  • C A Given
  • W H Brooks
  • M A Costa
  • H G Bezerra
چکیده

BACKGROUND AND PURPOSE Carotid artery-related stroke is largely an embolic disease that has been correlated with inflammation, plaque rupture, and thrombus formation in "vulnerable" atherosclerotic plaque. Nevertheless, current guidelines for carotid revascularization in asymptomatic patients rely on the calculation of stenosis for risk assessment, a parameter that has been viewed with increasing skepticism. Intravascular OCT is an imaging technique that offers high axial resolution (10 μm), allowing an unprecedented micron-level assessment of human carotid plaque morphology. This observational article reports the first successful use of the newest iteration of this technology, FDOCT without balloon occlusion to assess human carotid artery disease and carotid stent-vessel interaction in vivo. MATERIALS AND METHODS Four patients with asymptomatic carotid artery disease and ambiguous noninvasive and/or angiographic data underwent carotid FDOCT to assess risk and to formulate a treatment strategy. RESULTS Findings include the unexpected demonstration of TCFAs, plaque rupture, thrombus, inflammation, and marked tissue prolapse through stent struts in patients without high-risk factors by conventional criteria, as well as low-risk features in a patient with a high-risk noninvasive study. The procedures were performed without safety issues or special accommodations for vessel occlusion. CONCLUSIONS The present study demonstrates the technical feasibility of FDOCT in cervical carotid arteries. As such, this technology holds the promise of not only clarifying ambiguous data in individual patients but of providing data that might call for a future paradigm shift in the assessment of asymptomatic carotid artery disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advanced Imaging of Intracranial Atherosclerosis: Lessons from Interventional Cardiology

Intracranial atherosclerosis is a major cause of ischemic stroke. Patients with a high degree of stenosis have a significant rate of stroke despite medical therapy. Two randomized trials of stenting have failed to show benefit. Improving periprocedural complication rates and patient selection may improve stenting outcomes. Fractional flow reserve (FFR), intravascular ultrasound (IVUS), and opti...

متن کامل

Assessment of coronary plaque with optical coherence tomography and high-frequency ultrasound.

This study compares the ability of intravascular optical coherence tomography (OCT) and high-frequency intravascular ultrasound (IVUS) to image highly stenotic human coronary arteries in vitro. Current imaging modalities have insufficient resolution to perform risk stratification based on coronary plaque morphology. OCT is a new technology capable of imaging at a resolution of 5 to 20 microm, w...

متن کامل

CLINICAL REPORT EXTRACRANIAL VASCULAR Frequency-Domain Optical Coherence Tomography Assessment of Human Carotid Atherosclerosis Using Saline Flush for Blood Clearance without BalloonOcclusion

SUMMARY FD-OCT is a new imaging technique that allows unprecedented in vivo microlevel assessment of human carotid plaque morphologic patterns and stent-vessel interactions. Prior reports describing the use of this technique have used balloon occlusion of the target vessel or iodinated contrast media to facilitate imaging. We report, for the first time, in vivo FD-OCT imaging of human carotid a...

متن کامل

The basics of intravascular optical coherence tomography

Optical coherence tomography (OCT) has opened new horizons for intravascular coronary imaging. It utilizes near-infrared light to provide a microscopic insight into the pathology of coronary arteries in vivo. Optical coherence tomography is also capable of identifying the chemical composition of atherosclerotic plaques and detecting traits of their vulnerability. At present it is the only tool ...

متن کامل

INTERVENTIONAL CARDIOLOGY AND SURGERY Evaluation of intracoronary stenting by intravascular optical coherence tomography

Background: Conventional contrast cineangiography and intravascular ultrasound (IVUS) provide a limited definition of vessel microstructure and are unable to evaluate dissection, tissue prolapse, and stent apposition on a size scale less than 100 μm. Objective: To evaluate the use of intravascular optical coherence tomography (OCT) to assess the coronary arteries in patients undergoing coronary...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 33 8  شماره 

صفحات  -

تاریخ انتشار 2012