Roche RIA and Abbott EIA carcinoembryonic antigen assays compared.

نویسندگان

  • M Fleisher
  • J S Nisselbaum
  • L Loftin
  • C Smith
  • M K Schwartz
چکیده

We have evaluated Roche Diagnostics' RIA-CEA and Abbott Diagnostics' EIA-CEA methods for precision, normal reference interval, concordance, and correlation of malignant disease with increase in carcinoembryonic antigen (CEA) in plasma. In examining concordance, we used data on 138 patients with primary carcinomas of the breast, colon, lung, or pancreas, each further classified by extent of dissemination. We find the two methods to be comparably precise. The respective upper reference limits of normal for the Roche and Abbott methods were determined to be 5.0 micrograms/L and 4.6 micrograms/L. The regression equation for a log transformation of the 177 data points is y = 0.966x + 0.03, where x = Roche and y = Abbott, with a correlation coefficient of 0.948. According to the criteria we used, the concordance was 78.7%. The largest discordance was observed in widely disseminated disease states and in cancers of the colon and pancreas. Paired data analysis of discordance indicated greater increases in apparent CEA by the Abbott method in most colon cancers with liver involvement; six of the eight discordant pancreatic cancers had higher Roche-CEA values. CEA heterogeneity and the role of the liver in CEA metabolism appear to contribute to the observed differences. We show why the two methods should not be used interchangeably, and that baseline values for CEA must be established for each method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Solving the problem of antibody interference in commercial "sandwich"-type immunoassays of carcinoembryonic antigen.

We evaluated the effect of human anti-murine antibodies (HAMA) on apparent concentrations of carcinoembryonic antigen (CEA) as measured in serum with commercial enzyme immunoassay (EIA) kits manufactured by Abbot ("two-step" double monoclonal antibody assay), Roche, and Hybritech (room-temperature protocol). In sera from patients given parenteral murine monoclonal antibody for experimental diag...

متن کامل

Discrepancies in carcinoembryonic antigen measurements: survey and control values vs values for patients.

We analyzed the carcinoembryonic antigen (CEA) test results reported in the College of American Pathologists' (CAP) surveys to determine the relationship between the source of CEA used to manufacture the survey specimens and the discrepancies among analytical methods. With the 1983 survey specimens, which were prepared from metastatic colon carcinoma, laboratories using Roche RIA with Clinetics...

متن کامل

Enzyme immunoassay for anti-hepatitis B core (HBc) immunoglobulin G1 and significance of low-level results in competitive assays for anti-HBc.

An enzyme immunoassay (EIA) for anti-hepatitis B core (HBc) immunoglobulin G1 (IgG1) was compared with a commercial radioimmunoassay (RIA) for anti-HBc antibody (Corab: Abbott Laboratories, North Chicago, Ill.). In parallel tests of 445 consecutive samples, discrepant results were obtained with 2 samples, 1 of which was positive only by the RIA and the other of which was positive only by the EI...

متن کامل

An enzyme immunoassay procedure for cancer antigen 125 evaluated.

The performance of a new enzyme immunoassay (EIA) procedure (Abbott Labs.) for cancer antigen 125 (CA 125) met or exceeded the manufacturer's claims for all analytical variables examined. Overall correlation with results obtained with a radioimmunoassay (RIA) were good. However, near the decision thresholds typically chosen to define a positive result for ovarian carcinoma, EIA results were 10 ...

متن کامل

State-of-the-art vitamin D assays: a comparison of automated immunoassays with liquid chromatography-tandem mass spectrometry methods.

BACKGROUND Vitamin D testing is increasing worldwide. Recently several diagnostic manufacturers including Abbott and Siemens have launched automated 25-hydroxy vitamin D (25OH-D) immunoassays. Furthermore, preexisting assays from DiaSorin and Roche have recently been modified. We compared the performance of 5 automated immunoassays, an RIA and 2 liquid chromatography-tandem mass spectrometry (L...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 30 2  شماره 

صفحات  -

تاریخ انتشار 1984