The influence of incision-induced astigmatism and axial lens position on the correction of myopic astigmatism with the Artisan toric phakic intraocular lens.

نویسندگان

  • Marjolijn C Bartels
  • Ruchi Saxena
  • Thomas J T P van den Berg
  • Gabriel van Rij
  • Paul G H Mulder
  • Gregorius P M Luyten
چکیده

PURPOSE To evaluate postoperative astigmatism with regard to incision-induced astigmatism and deviation in axial alignment with the use of preoperative limbal marking with the Javal keratometer (Haag Streit, Bern, Switzerland) in eyes implanted with the Artisan toric phakic intraocular lens (IOL) (Ophtec, Groningen, The Netherlands). DESIGN Prospective nonrandomized trial. PARTICIPANTS Fifty-four eyes of 33 patients with myopia (mean, -9.67 diopters [D]) and astigmatism (mean, -3.44 D). INTERVENTION The enclavation site was marked on the limbus using the Javal keratometer. The Artisan toric phakic IOL was implanted according to the axis marked on the limbus. Follow-up was a minimum of 6 months. MAIN OUTCOME MEASURES Safety index, efficacy index, predictability, safety, and vector analysis of total refractive correction were determined. The effects of axis misalignment and incision-induced astigmatism on the final refractive error were evaluated. RESULTS At 6 months after surgery, the safety index was 1.29+/-0.29 and the efficacy index was 1.04+/-0.35. Mean spherical equivalent subjective refraction reduced from -11.39+/-4.86 D before surgery to -0.38+/-0.57 D at 6 months. Sixty-seven percent of eyes were within 0.50 D of attempted refraction and 89% were within 1.00 D. Mean preoperative cylinder was 2.92+/-1.60 D at 91.4 degrees . At 6 months, the mean cylinder was 0.28+/-0.54 D at 174.3 degrees . No eyes lost 2 or more lines of best-corrected visual acuity at 6 months. Eighty-three percent of eyes achieved uncorrected visual acuity of 20/40 and 28% achieved 20/20. Vector analysis of total surgically induced astigmatism revealed a mean cylindrical change of 3.21+/-1.71 D. Average axis misalignment was 0.37+/-5.34 degrees . The mean incision-induced astigmatism was 0.74+/-0.61 D at 0.2 degrees . CONCLUSIONS Implantation of the myopic toric IOL leads to safe, efficacious, and predictable results. The level of unpredictability caused by minor axis IOL misalignment has minimal effects on the residual refractive error. The procedure of axis alignment with the Javal keratometer seems to be an accurate method of marking the eye for toric IOL implantation. Incision-induced astigmatism can result in an overcorrection of the cylinder. A systematic undercorrection of -0.50 D for attempted cylindrical outcome could result in an achieved correction closer to emmetropia.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artisan toric phakic intraocular lens for the correction of high astigmatism.

PURPOSE To evaluate efficacy, predictability, and safety of Artisan toric phakic intraocular lens (Ophtec, Groningen, The Netherlands) implantation for the correction of astigmatism higher than 2 diopters. DESIGN Interventional case series. METHODS This prospective study included 27 eyes of 16 patients with a mean preoperative spherical equivalent of -11.78 +/- 6.24 diopters and a mean preo...

متن کامل

Vector analysis of corneal and refractive astigmatism changes following toric pseudophakic and toric phakic IOL implantation.

PURPOSE To determine the efficacy of the astigmatism correction following toric intraocular lens (IOL) and toric phakic IOL (pIOL) implantation in eyes with no previous ocular surgery and in postkeratoplasty (PKP) eyes. In addition, changes in corneal astigmatism were determined. METHODS Astigmatism was analyzed in 35 eyes with an AcrySof toric IOL, 35 eyes with an Artiflex toric pIOL, 50 eye...

متن کامل

Outcomes of iris-fi xated toric phakic intraocular lens implantation in the correction of myopic astigmatism

METHODS: Retrospective analysis of data from patients who underwent toric iris-fi xated pIOL (Artifl ex® and Artisan®) implantation in Centro Hospitalar Lisboa Central between 2009 and 2013. Th e main parameters evaluated were best corrected visual acuity (BCVA), uncorrected visual acuity (UCVA), manifest refraction, intraocular pressure (IOP), central endothelial cell count (ECC) and complicat...

متن کامل

Artisan iris-fixated toric phakic and aphakic intraocular lens implantation for the correction of astigmatic refractive error after radial keratotomy.

We report 2 patients who had radial keratotomy (RK) to correct myopia. The first patient developed a postoperative hyperopic shift and cataract. Nine years post RK, she had intracapsular cataract extraction and implantation of an Artisan aphakic intraocular lens (IOL). Twenty years post RK, hyperopia and astigmatism progressed to +7.0 -5.75 x 100 with a best corrected visual acuity (BCVA) of 20...

متن کامل

Artisan iris-fixated toric phakic intraocular lens for the correction of high astigmatism after deep anterior lamellar keratoplasty.

We report the refractive correction of high astigmatism in one eye of a 23-year-old woman following deep anterior lamellar keratoplasty (DALK) using an Artisan iris-fixated, toric, phakic intraocular lens (IOL). One year after implantation, uncorrected and corrected distance visual acuities were both 20/25, refraction was -1.00 D cylinder, and the endothelial cell count was 1827 cells/mm(2). Ir...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ophthalmology

دوره 113 7  شماره 

صفحات  -