Optimization of immunostaining on flat-mounted human corneas
نویسندگان
چکیده
PURPOSE In the literature, immunohistochemistry on cross sections is the main technique used to study protein expression in corneal endothelial cells (ECs), even though this method allows visualization of few ECs, without clear subcellular localization, and is subject to the staining artifacts frequently encountered at tissue borders. We previously proposed several protocols, using fixation in 0.5% paraformaldehyde (PFA) or in methanol, allowing immunostaining on flatmounted corneas for proteins of different cell compartments. In the present study, we further refined the technique by systematically assessing the effect of fixative temperature. Last, we used optimized protocols to further demonstrate the considerable advantages of immunostaining on flatmounted intact corneas: detection of rare cells in large fields of thousands of ECs and epithelial cells, and accurate subcellular localization of given proteins. METHODS The staining of four ubiquitous proteins, ZO-1, hnRNP L, actin, and histone H3, with clearly different subcellular localizations, was analyzed in ECs of organ-cultured corneas. Whole intact human corneas were fixed for 30 min in 0.5% paraformaldehyde or pure methanol at four temperatures (4 °C for PFA, -20 °C for methanol, and 23, 37, and 50 °C for both). Experiments were performed in duplicate and repeated on three corneas. Standardized pictures were analyzed independently by two experts. Second, optimized immunostaining protocols were applied to fresh corneas for three applications: identification of rare cells that express KI67 in the endothelium of specimens with Fuch's endothelial corneal dystrophy (FECD), the precise localization of neural cell adhesion molecules (NCAMs) in normal ECs and of the cytokeratin pair K3/12 and CD44 in normal epithelial cells, and the identification of cells that express S100b in the normal epithelium. RESULTS Temperature strongly influenced immunostaining quality. There was no ubiquitous protocol, but nevertheless, room temperature may be recommended as first-line temperature during fixation, instead of the conventional -20 °C for methanol and 4 °C for PFA. Further optimization may be required for certain target proteins. Optimized protocols allowed description of two previously unknown findings: the presence of a few proliferating ECs in FECD specimens, suggesting ineffective compensatory mechanisms against premature EC death, and the localization of NCAMs exclusively in the lateral membranes of ECs, showing hexagonal organization at the apical pole and an irregular shape with increasing complexity toward the basal pole. Optimized protocols were also effective for the epithelium, allowing clear localization of cytokeratin 3/12 and CD44 in superficial and basal epithelial cells, respectively. Finally, S100b allowed identification of clusters of epithelial Langerhans cells near the limbus and more centrally. CONCLUSIONS Fixative temperature is a crucial parameter in optimizing immunostaining on flatmounted intact corneas. Whole-tissue overview and precise subcellular staining are significant advantages over conventional immunohistochemistry (IHC) on cross sections. This technique, initially developed for the corneal endothelium, proved equally suitable for the corneal epithelium and could be used for other superficial mono- and multilayered epithelia.
منابع مشابه
Optimization of immunolocalization of cell cycle proteins in human corneal endothelial cells
PURPOSE En face observation of corneal endothelial cells (ECs) using flat-mounted whole corneas is theoretically much more informative than observation of cross-sections that show only a few cells. Nevertheless, it is not widespread for immunolocalization (IL) of proteins, probably because the endothelium, a superficial monolayer, behaves neither like a tissue in immunohistochemistry (IHC) nor ...
متن کاملA new donor cornea harvesting technique for posterior lamellar keratoplasty.
AIMS To describe a technique for posterior lamellar keratoplasty donor preparation. METHODS In an experimental study eight human donor research corneas were mounted onto an artificial anterior chamber and deep stromal pockets dissected. Four corneas were mounted in the standard endothelial side down orientation and dissected using standard instruments (group 1). Another four corneas were moun...
متن کاملIn situ immunohistochemical study of Bcl-2 and heat shock proteins in human corneal endothelial cells during corneal storage.
AIM To investigate the expression of Bcl-2 and heat shock proteins (HSPs), which are known to increase cell survival, in human corneal endothelial cells (HCECs) of corneas stored in organ culture. METHODS 32 paired corneas were randomly assigned to either a short or a long storage time. The flat mounts of endothelium were examined after immunostaining with monoclonal antibodies to Bcl-2 and H...
متن کاملDesign Optimization of Axial Flux Surface Mounted Permanent Magnet Brushless DC Motor For Electrical Vehicle Based on Genetic Algorithm
This paper presents the design optimization of axial flux surface mounted Permanent Magnet Brushless DC motor based on genetic algorithm for an electrical vehicle application. The rating of the motor calculated form vehicle dynamics is 250 W, 150 rpm. The axial flux surface mounted Permanent Magnet Brushless DC (PMBLDC) motor was designed to fit in the rim of the wheel. There are several design...
متن کاملExpression of SFRP Family Proteins in Human Keratoconus Corneas
We investigated the expression of the secreted frizzled-related proteins (SFRPs) in keratoconus (KC) and control corneas. KC buttons (∼8 mm diameter) (n = 15) and whole control corneas (n = 7) were fixed in 10% formalin or 2% paraformaldehyde and subsequently paraffin embedded and sectioned. Sections for histopathology were stained with hematoxylin and eosin, or Periodic Acid Schiff's reagent. ...
متن کامل