Simple and Sensitive Lc–uv Method for Simultaneous Analysis of Hydrochlorothiazide and Candesartan Cilexetil in Pharmaceutical Formulations

نویسندگان

  • S. S. Qutab
  • S. N. Razzaq
  • M. Ashfaq
  • Z. A. Shuja
  • I. U. Khan
چکیده

A simple, sensitive, and inexpensive high-performance liquid-chromatographic method has been developed for simultaneous determination of hydrochlorothiazide and candesartan cilexetil in pharmaceutical formulations. Chromatographic separation was achieved on a Phenyl-2 column with a 25:75:0.2 mixture of 0.02 M potassium dihydrogen phosphate, methanol, and triethylamine, final pH 6.0 ± 0.1, as mobile phase. Detection was at 271 nm. Response was a linear function of concentration in the range 5–45 μg mL for hydrochlorothiazide and 12–56 μg mL for candesartan cilexetil; the correlation coefficients were 0.9993 and 0.9991, respectively. Total elution time for the two components was less than 5 min.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

DEVELOPMENT AND VALIDATION OF A RP-HPLC METHOD FOR ESTIMATION OF HYDROCHLOROTHIAZIDE AND CANDESARTAN CILEXETIL IN PHARMACEUTICAL DOSAGE FORM *Ananda Rao Bonthala and T.A.D

A simple, specific and accurate reverse phase high performance liquid chromatographic method was developed for the simultaneous determination of hydrochlorothiazide and candesartan cilexetil in pharmaceutical dosage form. The column used was Zorbax C8 (150×4.6 mm, 3.5μm) in isocratic mode, with mobile phase containing phosphate buffer-methanol (30:70) adjusted to pH 3.0 using ortho phosphoric a...

متن کامل

Development and Validation of a Stability-indicating UV Spectroscopic Method for Candesartan in Bulk and Formulations

A simple, specific, accurate and stability-indicating UV- Spectrophotometric method was developed for the estimation of candesartan cilexitil, using a Shimadzu, model 1700 spectrophotometer and a mobile phase composed of methanol: water in the ratio of 9:1 at wave length (λ(max)) 254 nm. Linearity was established for candesartan in the range of 10-90 μg/ml. The percentage recovery of was found ...

متن کامل

Spectrofluorimetric method for determination of some angiotensin II receptor antagonists

A simple, rapid, accurate and highly sensitive spectrofluorimetric method has been developed for determination of some angiotensin II receptor antagonists (AIIRA's), namely Losartan potassium (Los-K), Irbesartan (Irb), Valsartan (Val) and Candesartan cilexetil (Cand) in pure forms as well as in their pharmaceutical dosage forms. All the variables affecting the relative fluorescence intensity (R...

متن کامل

Simultaneous Determination of Losartan and Hydrochlorothiazide in Pharmaceutical Preparations by Derivative and Ratio Derivative Spectrophotometry

Background & Aims: Losartan is a non-peptide potent antihypertensive agent that acts through blocking angiotensin II receptors. Hyzaar® is a combination product that contains two drugs, losartan and hydrochlorothiazide, used to lower high blood pressure. There are some reports regarding simultaneous measurement of the drugs in pharmaceutical and biological samples which includes HPLC, CE, CEC, ...

متن کامل

Simultaneous Determination of Hydrochlorothiazide and Enalapril Maleate in Pharmaceutical Formulations Using Fourier Transform Infrared Spectrometry

A new Fourier Transform-Infra Red (FT-IR) spectrometric method was developed for assaying hydrochlorothiazide (HCT) and enalapril maleate (ENM) in binary solid pharmaceutical formulations. Multivariate Partial Least Squares (PLS) method was used for calibration of derivative spectral data. Acetonitrile was used as solvent due to its spectral tran...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008