Ultraviolet exposure of Gafchromic XR‐RV3 and XR‐SP2 films
نویسندگان
چکیده
Gafchromic film has been used for X-ray dose measurement in diagnostic examinations. Their use has been initiated for three-dimensional X-ray dose measurement by using the high-resolution characteristics of Gafchromic films in computed tomography. However, it is necessary to solve the problem of nonuniform thickness in the active layers of Gafchromic films. A double exposure technique using X-rays is performed in therapeutic radiology; it is difficult to use in a diagnostic examination because of the heel effect. Therefore, it is suggested that ultraviolet (UV) rays be substituted for X-rays. However, the appropriate UV wavelength is unknown. In this study, we aimed to determine which UV wavelengths are effective to expose Gafchromic XR-RV3 and XR-SP2. UV lamps with peak wavelengths of 245 nm, 310 nm, and 365 nm were used. The three UV wavelengths were used to irradiate Gafchromic XR-RV3 and XR-SP2 films for 60 min, and irradiation was repeated every 60 min for 600 min thereafter. Films were scanned after each irradiation period on a flatbed scanner. The images were split into their red-green-blue components, and red images were stored using ImageJ version 1.44o image analysis software. Regions of interest (ROI), 0.5 inches in diameter, were placed at the centers of the subtracted Gafchromic film images, and graphs of UV irradiation duration and mean pixel values were plotted. There were reactions to UV-A on both Gafchromic XR-RV3 and XR-SP2; those to UV-B were moderate. However, UV-C demonstrated few reactions with Gafchromic XR-RV3 and XR-SP2. From these results, irradiation with UV-A may be able to correct nonuniformity errors. Uniform UV-A irradiation of Gafchromic films with large areas is possible, and UV rays can be used as a substitute for X-rays in the double exposure technique.
منابع مشابه
Dosimetric comparison between XR-RV3 and EBT2 radiochromic film in megavoltage photon beams
Background: Radiochromic film is used for radiation dose measurement, XR-RV3 is used in fluoroscopy and EBT2 film in radiation therapy. The aim was to determine if the dosimetric properties of these two films are comparable in megavolt photon beams. Materials and Methods: Comparison measurements included: calibration curves, heterogeneous phantom dose profiles, and nasopharynx dose distributio...
متن کاملDosimetric evaluation of GAFCHROMIC® XR type T and XR type R films
The high spatial resolution of radiochromic film makes it ideal for dosimetric measurements and dose distributions in regions of high dose gradient. Intensity-modulated radiation therapy, intravascular brachytherapy, and eye-plaque radiation therapy demand precise spatial dosimetric calculations. Such precision is not possible with conventional dosimeters, such as thermoluminescent dosimeters a...
متن کاملReflection spectrometry analysis of irradiated GAFCHROMIC XR type R radiochromic films.
The absorption spectra of the GAFCHROMIC XR type R radiochromic film measured with reflectance spectroscopy have been investigated in order to analyze the dosimetry characteristics of the film. Like the XR type T film, this film features two peaks in its absorption spectrum, approximately at 676 and 618 nm, whose intensities increase with increasing absorbed dose. When the main absorption peak ...
متن کاملDetermining rectal dose through cervix cancer radiotherapy by 9 MV photon beam using TLD and XR type T GAFCHROMIC® Film
Background: The goals of the present research were to investigate the rectal dose during four chosen techniques of cervical cancer radiotherapy and to examine how accurately the treatment planning represents dose measurements, and it’s practicality for routine use as well as, to determine the homogeneity of dose in tumor volume. Materials and Methods: The study was carried out using a Nepton 10...
متن کاملVerification of Indicated Skin Entrance Air Kerma for Cardiac X-ray-guided Intervention Using Gafchromic Film.
The aim of this work was to verify the indicated maximum entrance surface air kerma (ESAK) using a GE Innova IGS 520 imaging system during cardiac interventional procedures. Gafchromic XR RV3 films were used for the patient measurements to monitor the maximum ESAK. The films were scanned and calibrated to measure maximum ESAK. Thermoluminescent dosemeters were used to measure the backscatter fa...
متن کامل