Use of stereotactic radiosurgery in the treatment of gynecologic malignancies: A review.

نویسندگان

  • Beverly Long
  • Ramez N Eskander
  • Krishnansu S Tewari
چکیده

Recent retrospective studies have reported the use of stereotactic radiosurgery (SRS) in the treatment of gynecologic cancers. SRS uses real-time imaging and high dose radiation beams attached to precise robotic arms to target malignant lesions while sparing normal tissue. The purpose of this review is to examine the indications for SRS in gynecologic oncology, review the current literature regarding the use of SRS in gynecologic cancers, and identify future directions for research in this area. Literature on stereotactic radiosurgery was reviewed using the PubMed search engine. Articles written in English from 1993-2013 were reviewed, and 20 case series and clinical trials were included. The safety and efficacy SRS has been demonstrated in all gynecologic disease sites including cervical, endometrial, vulvar, vaginal, and ovarian cancers. Indications for its use include non-central pelvic recurrences in previously irradiated patients, complex or non-resectable disease recurrence, and solitary brain metastases. Toxicities are usually mild, though grade 3-4 toxicities have been reported. SRS is a promising second line treatment modality for patients with primary or recurrent disease who cannot undergo standard surgical or radiation therapy. Further research is required to determine optimal dosing and fractionation schedules, delineate appropriate patient populations, and assess longterm morbidity and survival.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stereotactic Radiosurgery/Radiotherapy: A Historical Review

"Stereotactic" is an exact radiotherapy treatment modality which implements invasive and non-invasive facilities for improving precise dose delivery. Stereotactic refers to three-dimensional localization of a specific point in space by a unique set of coordinates that relate to a fixed external reference frame. An accurate delivery of radiation is attainable using these techniques with high pre...

متن کامل

Development of A Head Docking Device for Linac-based Stereotactic Radiosurgery System to be Installed on Neptun 10 PC Linac

Introduction:  Stereotactic  radiosurgery  is  a  technique  for  the  treatment  of  intracranial  lesions  with  highly  collimated  x-ray  beam.  Linac-based  radiosurgery  is  currently  performed  by  two  techniques:  couch or pedestal mounted. In the first technique, a device is required to affix patient's head to a couch  and  moreover  to  translate  it  accurately.  Structure  of  suc...

متن کامل

Commentary: Phase I Trial of Carboplatin and Gemcitabine Chemotherapy and Stereotactic Ablative Radiosurgery for the Palliative Treatment of Persistent or Recurrent Gynecologic Cancer

Citation: Kunos CA (2016) Commentary: Phase I Trial of Carboplatin and Gemcitabine Chemotherapy and Stereotactic Ablative Radiosurgery for the Palliative Treatment of Persistent or Recurrent Gynecologic Cancer. Front. Oncol. 6:263. doi: 10.3389/fonc.2016.00263 Commentary: Phase I trial of Carboplatin and Gemcitabine Chemotherapy and Stereotactic ablative radiosurgery for the Palliative treatmen...

متن کامل

Design, Construction and Evaluation of an Anthropomorphic Head Phantom for Assessment of Image Distortion in Stereotactic Radiosurgery Planning Systems

Introduction: In recent years, the use of magnetic resonance (MR) images in radiation treatment planning has drawn considerable attention. However, although the extent of a tumor can be determined in great detail on MR images, the geometric accuracy of these images is limited by distortions stemming from the inhomogeneity of the static background magnetic field, the nonlineari...

متن کامل

Development of a prototype stereotactic collimation assembly for Neptun 10 PC linac

Background: A set of hardware stereotactic radiosurgery is designed and constructed. The scope of this article is to describe how we have designed and developed stereotactic collimation assembly for a 9 MV Neptun 10 PC linac. Materials and methods: One collimator holder and six collimators were made, with their radiation field diameter between 12.5 mm to 25 mm at isocenter level. Beam data, suc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • World journal of radiology

دوره 6 6  شماره 

صفحات  -

تاریخ انتشار 2014