Fetal Heart Monitoring From Maternal ECG
نویسندگان
چکیده
Observing fetal health is very important for mothers and the fetus well-being. Most of the conditions can be monitored via ECG, so Fetal ECG extraction plays an important role. Extracting Fetal ECG implies filtering maternal ECG and other artifacts and due to the presence of reference signal which is mothers ECG from chest adaptive filter is used much often. This paper proposes adaptive noise cancellation technique using LMS algorithm and heart rate detection algorithm. The method can also be used for a model based design to achieve result on hardware platform.
منابع مشابه
A PCA/ICA based Fetal ECG Extraction from Mother Abdominal Recordings by Means of a Novel Data-driven Approach to Fetal ECG Quality Assessment
Background: Fetal electrocardiography is a developing field that provides valuable information on the fetal health during pregnancy. By early diagnosis and treatment of fetal heart problems, more survival chance is given to the infant.Objective: Here, we extract fetal ECG from maternal abdominal recordings and detect R-peaks in order to recognize fetal heart rate. On the next step, we find a be...
متن کاملIntrapartum heart rate ambiguity: a comparison of cardiotocogram and abdominal fetal electrocardiogram with maternal electrocardiogram.
OBJECTIVE/AIMS To investigate the presence of signal ambiguity of intrapartum fetal heart rate (FHR) monitoring during delivery by comparing simultaneous cardiotocogram (CTG), abdominal fetal electrocardiogram (ECG) with continuous maternal ECG. METHODS A total of 144 simultaneous CTG (Corometrics 250 series), abdominal fetal ECG (Monica -AN24™) and maternal ECG (Monica AN24™) recordings were...
متن کاملSolution of Controversy in Fetal Heart Rate Patterns
Fetal well-being was estimated by the enlargement of maternal abdomen, palpation of fetus on the abdomen, maternal perception of fetal kicking, and listening to fetal heart sound with obstetric stethoscope, in old age. Antique diagnosis of fetal life was fetal QRS found on limb lead electrocardiogram (ECG) studied by Cremer, which was progressed to fetal ECG amplifier composed of vacuum tube re...
متن کاملComment on the article "accuracy and reliability of fetal heart rate monitoring using maternal abdominal surface electrodes".
OBJECTIVE Compare the accuracy and reliability of fetal heart rate identification from maternal abdominal fetal electrocardiogram signals (ECG) and Doppler ultrasound with a fetal scalp electrode. DESIGN Prospective open method equivalence study. SETTING Three urban teaching hospitals in the Northeast United States. SAMPLE 75 women with normal pregnancies in labor at >37 weeks of gestatio...
متن کاملApparatus for Continuous Monitoring of the Fetal Heart Rate *
APPARATUS FOR CONTINUOUS MONITORING OF THE FETAL HEART RATE.* By Edward H. Hon, Department of Obstetrics and Gynecology, Yale University School of Medicine. During the past four years continuous monitoring of fetal heart rate during labor and delivery has permitted the accumulation of accurate, permanent records which may be of value for the assessment of fetal heart rate as an index of fetal e...