Possible role of vacuum systems and compressed air generators in cross-infection in the ICU. A radioactive tracer study.

نویسندگان

  • P Bjerring
  • B Oberg
چکیده

Cross-contamination between a hospital's vacuum and compressed air systems was demonstrated using xenon-133 as a tracer. A xenon-133 bolus was introduced to the vacuum system in the intensive care unit. Calculations based on the amount of radioactive tracer recovered from the compressed air outlet at the same location as that at which the tracer was introduced indicated that 17% of the tracer had entered the compressed air system. The contamination was caused because the vacuum and compressed air systems were located in the same machine room. This could conceivably provide a route for respiratory tract contamination in patients receiving ventilatory assistance with air-oxygen mixtures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Overview of Novel Energy Storage Systems with Air Compression Method

With the increasing use of renewable energy systems and the volatility of access to this type of energy, needs energy storage systems to sustain the system. In the meantime, energy storage systems have distinct characteristics and applications, one of which is the compressed air energy storage system. In the present paper, the newest researches and novel systems in the field of energy storage b...

متن کامل

Day-ahead economic dispatch of coupled desalinated water and power grids with participation of compressed air energy storages

Nowadays, water and electricity are closely interdependent essential sources in human life that affect socio-economic growth and prosperity. In other words, electricity is a fundamental source to supply a seawater desalination process, while fresh water is used for cooling this power plant. Therefore, mutual vulnerability of water treatment and power generation systems is growing because of inc...

متن کامل

The Effect of Media System on the Performance and Pollutant ‎Emissions of v94.2 Gas Generators in Ansaldo Unit of Yazd ‎Combined Cycle Power Plant

Due to the increasing importance of energy, optimizing power generation systems and reducing their internal energy consumption are essential issues. Analysis of power generation systems is necessary regarding energy and recognition of their functioning. The present study investigated the effect of media system on the performance and emissions of environmental pollutants in Thermoflow Software b...

متن کامل

Security-Constrained Unit Commitment Considering Large-Scale Compressed Air Energy Storage (CAES) Integrated With Wind Power Generation

Environmental concerns and depletion of nonrenewable resources has made great interest towards renewable energy resources. Cleanness and high potential are factors that caused fast growth of wind energy. However, the stochastic nature of wind energy makes the presence of energy storage systems (ESS) in wind integrated power systems, inevitable. Due to capability of being used in large-scale sys...

متن کامل

A Risk for Nosocomial Infections: Contamination of Hospital Air Cooling Systems by Acantamoeba spp.

Background and Objectives: In the most Iranian hospitals the internal air is cooled by a system comprising centrifugal blower fan and excelsior filters. Because amoeba can be present in air and dust it may enter into filters of cooling systems. It has been suggested that diffusion of amoebae cyst through air canals may contribute to various types of nosocomial infections. This ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 59 5  شماره 

صفحات  -

تاریخ انتشار 1987