Quantitation of mitral regurgitation after percutaneous MitraClip repair: comparison of Doppler echocardiography and cardiac magnetic resonance imaging.

نویسندگان

  • Christian Hamilton-Craig
  • Wendy Strugnell
  • Niranjan Gaikwad
  • Matthew Ischenko
  • Vicki Speranza
  • Jonathan Chan
  • Johanne Neill
  • David Platts
  • Gregory M Scalia
  • Darryl J Burstow
  • Darren L Walters
چکیده

OBJECTIVE Percutaneous valve intervention for severe mitral regurgitation (MR) using the MitraClip is a novel technology. Quantitative assessment of residual MR by transthoracic echocardiography (TTE) is challenging, with multiple eccentric jets and artifact from the clips. Cardiovascular magnetic resonance (CMR) is the reference standard for left and right ventricular volumetric assessment. CMR phase-contrast flow imaging has superior reproducibility for quantitation of MR compared to echocardiography. The objective of this study was to establish the feasibility and reproducibility of CMR in quantitating residual MR after MitraClip insertion in a prospective study. METHODS Twenty-five patients underwent successful MitraClip insertion. Nine were excluded due to non-magnetic resonance imaging (MRI) compatible implants or arrhythmia, leaving 16 who underwent a comprehensive CMR examination at 1.5 T (Siemens Aera) with multiplanar steady state free precession (SSFP) cine imaging (cine CMR), and phase-contrast flow acquisitions (flow CMR) at the mitral annulus atrial to the MitraClip, and the proximal aorta. Same-day echocardiography was performed with two-dimensional (2D) visualization and Doppler. CMR and echocardiographic data were independently and blindly analyzed by expert readers. Inter-rater comparison was made by concordance correlation coefficient (CCC) with 95% confidence intervals (CIs), and Bland-Altman (BA) methods. RESULTS Mean age was 79 years, and mean LVEF was 44%±11% by CMR and 54%±16% by echocardiography. Inter-observer reproducibility of echocardiographic visual categorical grading by expert readers was poor, with a CCC of 0.475 (-0.7, 0.74). Echocardiographic Doppler regurgitant fraction reproducibility was modest (CCC 0.59, 0.15-0.84; BA mean difference -3.7%, -38% to 31%). CMR regurgitant fraction reproducibility was excellent (CCC 0.95, 0.86-0.98; BA mean difference -2.4%, -11.9 to 7.0), with a lower mean difference and narrower limits of agreement compared to echocardiography. Categorical severity grading by CMR using published ranges had good inter-observer agreement (CCC 0.86, 0.62-0.95). CONCLUSIONS CMR performs very well in the quantitation of MR after MitraClip insertion, with excellent reproducibility compared to echocardiographic methods. CMR is a useful technique for the comprehensive evaluation of residual regurgitation in patients after MitraClip. Technical limitations exist for both techniques, and quantitation remains a challenge in some patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

UDRUŽENJE KARDIOLOGA SRBIJE CARDIOLOGY SOCIETY OF SERBIA Percutaneous repair of mitral regurgitation with the Mitraclip system: clinical indications and first Slovenian experience

Corresponding author: Jana Ambrožič, Zaloška 7, 1000 Ljubljana, Slovenia, e-mail: [email protected] The MitraClip is the first percutaneous therapy for mitral regurgitation. It can be used in both etiologies: primary (degenerative) and secondary (functional) mitral regurgitation. The technique mimics surgical suture-based approach by implanting a clip that grasps free edges of both leafle...

متن کامل

اثر PercutaneousCoronary Intervention Elective بر بهبودی نارسایی ایسکمیک میترال

Introdution: Ischemic mitral regurgitation (IMR) remains one of the most complex and unresolved aspects of ischemic heart disease that the impact of percutaneous coronary intervention (PCI) on improvement of intensity of ischemic mitral regurgitation is not well clarified. Patients with coronary artery diseases and ischemic mitral regurgitation have a worse prognosis than the patients with coro...

متن کامل

Analysis of procedural effects of percutaneous edge-to-edge mitral valve repair by 2D and 3D echocardiography.

BACKGROUND Analysis of procedural effects in patients undergoing percutaneous mitral valve repair (PMVR) using the edge-to-edge technique is complex, and common methods to define mitral regurgitation severity based on 2-dimensional (2D) echocardiography are not validated for postprocedural double-orifice mitral valve. This study used 3D transesophageal echocardiography (TEE) to determine the fu...

متن کامل

Left ventricular remodeling following percutaneous edge-to-edge repair using Mitraclip

Methods Consecutive patients scheduled for MitraClip were prospectively studied. Patients with pacemaker or ICD were excluded. Transthoracic echocardiography and CMR at 1.5 Tesla were performed before and 6 months after MitraClip procedure. Left ventricular volumes were measured using transthoracic echocardiography (biplane Simpson’s method) and short-axis SSFP CMR images covering the left vent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of cardiothoracic surgery

دوره 4 4  شماره 

صفحات  -

تاریخ انتشار 2015