A generalised instantaneous non-active power theory for STATCOM
نویسنده
چکیده
A generalised instantaneous non-active power theory is presented. Comprehensive definitions of instantaneous active and non-active currents, as well as instantaneous, average and apparent powers, are proposed. These definitions have flexible forms that are applicable to different power systems, such as single-phase or multi-phase, periodic or non-periodic and balanced or unbalanced systems. By changing the averaging interval and the reference voltage, various non-active power theories can be derived from this theory. The definitions of instantaneous active and nonactive currents provide an algorithm for a STATCOM to calculate the non-active current in the load current. The theory is implemented by the STATCOM, and four cases (three-phase balanced RL load, three-phase unbalanced RL load, diode rectifier load and single-phase load) are tested. The experimental results show that the STATCOM can perform instantaneous non-active power compensation, and both the fundamental non-active component and the harmonics are eliminated from the utility so that nearly unity power factor can be achieved. The STATCOM also has a fast dynamic response for transients.
منابع مشابه
A Novel Controller Based on Single-Phase Instantaneous p-q Power Theory for a Cascaded PWM Transformer-less STATCOM for Voltage Regulation
In this paper, dynamic performance of a transformerless cascaded PWM static synchronous shunt compensator (STATCOM) based on a novel control scheme is investigated for bus voltage regulation in a 6.6kV distribution system. The transformerless STATCOM consists of a thirteen-level cascaded H-bridge inverter, in which each voltage source H-bridge inverter should be equipped with a floating and iso...
متن کاملA New Strategy for Simultaneous Compensation of Instantaneous Reactive Power and Harmonics of Non-Linear Loads (RESEARCH NOTE)
This paper presents a new control method for simultaneous compensation of instantaneous reactive power and current harmonics by parallel active filters (PAFs). Reference compensating currents of PAF are calculated using the subtraction of instantaneous power from its average value. In this way, it is possible omitting high/low pass filter(s) from the control circuit of PAF, which usually result...
متن کاملA Grid-connected PV Power Supply based on Flying Capacitor multicell converter with modified MPPT based Control for Active Power Filtering
This paper presents a grid connected photovoltaic system, which acts as both power generator and active power filter (APF), based on Flying Capacitor Multicell (FCM) converter. Increase in the number of output voltage levels, natural self-balancing of flying capacitors and dc link voltage and lower power rating of components are the main futures of FCM converter compared with conventional multi...
متن کاملA Grid-connected PV Power Supply based on Flying Capacitor multicell converter with modified MPPT based Control for Active Power Filtering
This paper presents a grid connected photovoltaic system, which acts as both power generator and active power filter (APF), based on Flying Capacitor Multicell (FCM) converter. Increase in the number of output voltage levels, natural self-balancing of flying capacitors and dc link voltage and lower power rating of components are the main futures of FCM converter compared with conventional multi...
متن کاملA Novel Reference Current Calculation Method for Shunt Active Power Filters using a Recursive Algebraic Approach
This paper presents a novel method to calculate the reference source current and the referencecompensating current for shunt active power filters (SAPFs). This method first calculates theamplitude and phase of the fundamental load current from a recursive algebraic approach blockbefore calculating the displacement power factor. Next, the amplitude of the reference mains currentis computed with ...
متن کامل