Threshold-level repetitive transcranial electrical stimulation for intraoperative monitoring of central motor conduction.

نویسندگان

  • B Calancie
  • W Harris
  • G F Brindle
  • B A Green
  • H J Landy
چکیده

OBJECT The authors conducted a study to evaluate repetitive transcranial electrical stimulation (TES) to assess spinal cord motor tract function in individuals undergoing spine surgery, with emphasis on safety and efficacy. METHODS Somatosensory evoked potentials (SSEPs) were elicited using standard technique. Muscle electromyographic values were measured in response to a three- or four-pulse train of stimulation delivered to the motor cortex via subdermal electrodes. They also evaluated whether changes in the minimum stimulus intensity (that is, threshold level) needed to elicit a response from a given muscle predict motor status immediately postoperatively, as well as whether changes in SSEP response amplitude and latency predict sensory status immediately postoperatively. Anesthesia was routinely induced with intravenous propofol and remifentanil, supplemented with inhaled nitrous oxide. Use of neuromuscular block was avoided after intubation. Satisfactory monitoring of muscle response to threshold-level repetitive TES was achieved in all but nine of the 194 patients studied. In contrast, cortical SSEP responses could not be elicited in 42 of 194 individuals. In cases in which responses were present, TES-based evoked responses proved to be extremely accurate for predicting postoperative motor status. Somatosensory evoked potential monitoring was nearly as accurate for predicting postoperative sensory status. There were frequent instances of postoperative motor or sensory deficit that were not predicted by SSEP- and TES-based monitoring, respectively. There were no adverse events attributable to TES-based monitoring, although since this study ended we have had a single adverse event attributable to threshold-level repetitive TES. CONCLUSIONS Intraoperative threshold-level repetitive TES-based monitoring of central motor conduction has proven to be a simple, safe, and highly accurate technique for the prevention or minimization of inadvertent motor deficit during surgery involving the spine or spinal cord.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic stimulation of the central and peripheral nervous systems.

Since 1985, when the technique of transcranial magnetic stimulation (TMS) was first developed, a wide range of applications in healthy and diseased subjects has been described. Comprehension of the physiological basis of motor control and cortical function has been improved. Modifications of the basic technique of measuring central motor conduction time (CMCT) have included measurement of the c...

متن کامل

The Effect of rTMS with Rehabilitation on Hand Function and Corticomotor Excitability in Sub-Acute Stroke

Objectives: Stroke is the leading cause of long-term disability. Hand motor impairment resulting from chronic stroke may have extensive physical, psychological, financial, and social implications despite available rehabilitative treatments. The best time to start treatment for stroke, is in sub-acute period. Repetitive transcranial magnetic stimulation (rTMS) is a method of stimulating and ...

متن کامل

Intravenous anaesthesia and repetitive transcranial magnetic stimulation monitoring in spinal column surgery.

BACKGROUND Transcranial magnetic stimulation with motor evoked potential monitoring is a non-invasive method for monitoring motor tracts during surgery. However, anaesthetic agents such as propofol and volatile agents reduce responses to single transcranial magnetic stimulation. We assessed an intravenous technique for anaesthesia to allow motor evoked potentials (MEPs) to be monitored using re...

متن کامل

Investigating the Effects of Low Frequency rTMS on Kindled Seizure in Rats

 Introduction: Neural stimulation is a promising new technology for the treatment of medically-intractable seizures.  Transcranial Magnetic Stimulation (TMS) is a simple, non-invasive, low cost technique which is widely used in neurophysiology. In a few studies that have been performed at different frequencies the therapeutic effects of this technique were not obvious. Repetition of low frequen...

متن کامل

Plastic Changes in Human Motor Cortical Output Induced by Random but not Closed-Loop Peripheral Stimulation: the Curse of Causality

Previous work showed that repetitive peripheral nerve stimulation can induce plastic changes in motor cortical output. Triggering electrical stimulation of central structures from natural activity can also generate plasticity. In this study, we tested whether triggering peripheral nerve stimulation from muscle activity would likewise induce changes in motor output. We developed a wearable elect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurosurgery

دوره 95 2 Suppl  شماره 

صفحات  -

تاریخ انتشار 2001