Measuring Patient Mobility in the ICU Using a Novel Noninvasive Sensor.
نویسندگان
چکیده
OBJECTIVES To develop and validate a noninvasive mobility sensor to automatically and continuously detect and measure patient mobility in the ICU. DESIGN Prospective, observational study. SETTING Surgical ICU at an academic hospital. PATIENTS Three hundred sixty-two hours of sensor color and depth image data were recorded and curated into 109 segments, each containing 1,000 images, from eight patients. INTERVENTIONS None. MEASUREMENTS AND MAIN RESULTS Three Microsoft Kinect sensors (Microsoft, Beijing, China) were deployed in one ICU room to collect continuous patient mobility data. We developed software that automatically analyzes the sensor data to measure mobility and assign the highest level within a time period. To characterize the highest mobility level, a validated 11-point mobility scale was collapsed into four categories: nothing in bed, in-bed activity, out-of-bed activity, and walking. Of the 109 sensor segments, the noninvasive mobility sensor was developed using 26 of these from three ICU patients and validated on 83 remaining segments from five different patients. Three physicians annotated each segment for the highest mobility level. The weighted Kappa (κ) statistic for agreement between automated noninvasive mobility sensor output versus manual physician annotation was 0.86 (95% CI, 0.72-1.00). Disagreement primarily occurred in the "nothing in bed" versus "in-bed activity" categories because "the sensor assessed movement continuously," which was significantly more sensitive to motion than physician annotations using a discrete manual scale. CONCLUSIONS Noninvasive mobility sensor is a novel and feasible method for automating evaluation of ICU patient mobility.
منابع مشابه
Design and Construction of a Novel Tactile Sensor for Measuring Contact-Force, Based on Piezoelectric Effect
In this paper, design and construction of a tactile sensor for measuring contact-force is presented. Mechanism of measuring contact-force in this tactile sensor is based on impedance changing of piezoelectric crystal and voltage of different points in circuit as a result of applying force on the crystal. By considering a specific point in the circuit and recording the changes of its voltage, ma...
متن کاملDesign, Modeling, and Construction of a New Tactile Sensor for Measuring Contact-Force
This paper presents the design, modeling, and testing of a flexible tactile sensor and its applications. This sensor is made of polymer materials and can detect the 2D surface texture image and contact-force estimation. The sensing mechanism is based on the novel contact deflection effect of a membrane. We measure the deflection of the membrane with measuring the strain in the membrane with emb...
متن کاملProcess Monitoring in the Intensive Care Unit: Assessing Patient Mobility Through Activity Analysis with a Non-Invasive Mobility Sensor
Throughout a patient's stay in the Intensive Care Unit (ICU), accurate measurement of patient mobility, as part of routine care, is helpful in understanding the harmful effects of bedrest [1]. However, mobility is typically measured through observation by a trained and dedicated observer, which is extremely limiting. In this work, we present a video-based automated mobility measurement system c...
متن کاملTarget Tracking Based on Virtual Grid in Wireless Sensor Networks
One of the most important and typical application of wireless sensor networks (WSNs) is target tracking. Although target tracking, can provide benefits for large-scale WSNs and organize them into clusters but tracking a moving target in cluster-based WSNs suffers a boundary problem. The main goal of this paper was to introduce an efficient and novel mobility management protocol namely Target Tr...
متن کاملDesign of Novel High Sensitive MEMS Capacitive Fingerprint Sensor
In this paper a new design of MEMS capacitive fingerprint sensors is presented. The capacitive sensor is made of two parallel plates with air gap. In these sensors, the capacitance changes is very important factor. It is caused by deformation of the upper electrode of sensor. In this study with making slots in upper electrode, using T-shaped protrusion on diaphragm in order to concentrate the f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Critical care medicine
دوره 45 4 شماره
صفحات -
تاریخ انتشار 2017