Removing spikes caused by quantization noise from high-resolution histograms.

نویسندگان

  • Daniel J Tozer
  • Paul S Tofts
چکیده

A novel method is presented for the removal of spikes, caused by the division of two series of integers, from high-resolution histograms. When two series of integers are divided the results take the form of a nonuniform distribution. Such a division is often used in medical imaging, due to the storage of most images as integers. An example of this is the division of the saturated and unsaturated signal intensities to obtain a magnetization transfer ratio. Histograms produced using these methods often contain spikes relating to the nonuniform distribution mentioned above. These spikes can have serious implications for certain histogram characteristics. Most commonly, peak height and location can be seriously distorted by these spikes, which have predictable locations. These spikes can be removed by the addition of uniformly distributed noise to the integer signal intensities before division.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Decrease in Hardware Consumption and Quantization Noise of Digital Delta-Sigma Modulators and Implementation by VHDL

A new structure is presented for digital delta-sigma modulator (DDSM). Novel architecture decreases hardware consumption, output quantization noise and spurs in Comparison to previous architectures. In order to reduce the delay, power consumption and increase maximum working frequency, the pipelining technique and the carry skip adder are used. Simulation proposed architecture shows that the qu...

متن کامل

On the Impact of Finite Receiver Resolution in Fading Channels

In this paper, we will consider the impact of finite resolution in a receiver analog-digital converter on the performance of square, linearly modulated systems over fading channels. We show that in fading channels, the probability of error in a quantized system cannot be reduced to zero due to the introduction of quantization noise, even for arbitrarily large SNR. The error floor occurs due to ...

متن کامل

An Enhanced Median Filter for Removing Noise from MR Images

In this paper, a novel decision based median (DBM) filter for enhancing MR images has been proposed. The method is based on eliminating impulse noise from MR images. A median-based method to remove impulse noise from digital MR images has been developed. Each pixel is leveled from black to white like gray-level. The method is adjusted in order to decide whether the median operation can be appli...

متن کامل

Efficient Linearisation of Sigma-Delta Modulators using Single-Bit Dither

Sigma-delta modulation, where a single-bit quantiser is embedded within a negative feedback loop (Fig. 1), is now a commonly-used technique for implementing high-resolution analogue-to-digital and digital-toanalogue converters (DACs), principally because of a favourable insensitivity to component tolerancing [1]. Single-bit quantisation generates relatively high levels of quantisation noise, he...

متن کامل

روشی نوین در کاهش نوفه رایسین از مقدار بزرگی سیگنال دیفیوژن در تصویربرداری تشدید مغناطیسی (MRI)

The true MR signal intensity extracted from noisy MR magnitude images is biased with the Rician noise caused by noise rectification in the magnitude calculation for low intensity pixels. This noise is more problematic when a quantitative analysis is performed based on the magnitude images with low SNR(<3.0). In such cases, the received signal for both the real and imaginary components will fluc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 50 3  شماره 

صفحات  -

تاریخ انتشار 2003