Performance of a Showerhead and Shaped Hole Film Cooled Vane at High Freestream Turbulence and Transonic Conditions

نویسنده

  • Andrew Newman
چکیده

An experimental study was performed to measure surface Nusselt number and film cooling effectiveness on a film cooled first stage nozzle guide vane using a transient thin film gauge (TFG) technique. The information presented attempts to further characterize the performance of shaped hole film cooling by taking measurements on a row of shaped holes downstream of leading edge showerhead injection on both the pressure and suction surfaces (hereafter PS and SS) of a 1 stage NGV. Tests were performed at engine representative Mach and Reynolds numbers and high inlet turbulence intensity and large length scale at the Virginia Tech Transonic Cascade facility. Three exit Mach/Reynolds number conditions were tested: 1.0/1,400,000; 0.85/1,150,000; and 0.60/850,000 where Reynolds number is based on exit conditions and vane chord. At Mach/Reynolds numbers of 1.0/1,450,000 and 0.85/1,150,000 three blowing ratio conditions were tested: BR = 1.0, 1.5, and 2.0. At a Mach/Reynolds number of 0.60/850,000, two blowing ratio conditions were tested: BR = 1.5 and 2.0. All tests were performed at inlet turbulence intensity of 12% and length scale normalized by leading edge diameter of 0.28. Film cooling effectiveness and heat transfer results compared well with previously published data, showing a marked effectiveness improvement (up to 2.5x) over the showerhead only NGV and agreement with published showerhead-shaped hole data. Net heat flux reduction was shown to increase substantially (average 2.6x) with the addition of shaped holes, with an increase (average 1.6x) in required coolant mass flow. Heat transfer and effectiveness augmentation with increasing blowing ratio was shown on the pressure side, however the suction side was shown to be less sensitive to changing blowing ratio. Boundary layer transition location was shown to be within a consistent region on the suction side regardless of blowing ratio and exit Mach number.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heat Transfer Measurements Using Thin Film Gauges and Infrared Thermography on a Film Cooled Transonic Vane

This work presents a comparison of thin film gauge (TFG) and infrared (IR) thermography measurement techniques to simultaneously determine heat transfer coefficient and film cooling effectiveness. The first comparison was with an uncooled vane where heat transfer coefficient was measured at Mex=0.77 and Tu=16%. Relatively good agreement was found between the results of the two methods and the e...

متن کامل

On Film Cooling of Turbine Guide Vanes - From Experiments and CFD-Simulations to Correlation Development

To achieve high thermal efficiency in modern gas turbines, the turbine-inlet temperature has to be increased. In response to such requisites and to prevent thermal failure of the components exposed to hot gas streams, the use of different cooling techniques, including film cooling, is essential. Finding an optimum film cooling design has become a challenge as it is influenced by a large number ...

متن کامل

Critical Drag Investigation for an Axisymmetric Projectile with Choked Base Bleed at High-Subsonic and Transonic Regime Using SST K-? Model

In the following paper, the effects of a choked jet exhausted from the base of a non-lifting body on its total and base drags at sub-sonic and transonic regimes has been numerically investigated. Having surveyed the results of some turbulence models and after comparing with experimental results, an appropriate turbulence model i.e. SST K-?, has been chosen and this model has been used in the su...

متن کامل

Effect of Turbulence Intensity on Cross-Injection Film Cooling at a Stepped or Smooth Endwall of a Gas Turbine Vane Passage

This study is concerned with a film cooling technique applicable to the protection of the endwalls of a gas turbine vane. In the experiments, cross-injection coolant flow from two-row, paired, inclined holes with nonintersecting centerlines was utilized. The test model is a scaled two-half vane. The levels of turbulence intensity used in the experiments are T.I. = 1.8%, 7%, and 12%. Other param...

متن کامل

Turbine Airfoil External Heat Transfer Measurement in a Hot - Cascade Iii

Detailed knowledge of local external heat transfer around a turbine airfoil is critical for an accurate prediction of metal temperature and component life. This paper discusses the results of measurements of the local gas side heat transfer coefficient distribution which were performed in an annular gas turbine vane hot-cascade test facility and provides comparisons with analytical predictions....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010