Pressure phosphene tonometry versus Goldmann applanation tonometry for measuring intraocular pressure before and after LASIK.

نویسندگان

  • Gabi Shemesh
  • Oran Man
  • Adi Michaeli
  • David Varssano
  • Moshe Lazar
چکیده

PURPOSE To compare pressure phosphene tonometry with Goldmann applanation tonometry for measuring intraocular pressure (IOP) before and after LASIK. METHODS Forty-three (18 men and 25 women) consecutive healthy patients underwent complete pre- and postoperative LASIK ophthalmologic assessments including manifest and cycloplegic refraction, keratometry, and central corneal thickness. Three repetitive sets of pressure phosphene tonometry and Goldmann applanation tonometry measurements were performed the day before and 3 months following uneventful LASIK. RESULTS Mean preoperative spherical equivalent refraction was -4.70 +/- 2.50 diopters (D) (range: -1.50 to -12.90 D) and mean preoperative keratometry was 43.95 +/- 1.08 D. After LASIK, spherical equivalent refraction was +0.23 +/- 0.11 D and mean keratometry was 39.46 +/- 2.28 D. Preoperative pressure phosphene tonometry (12.16 +/- 1.58 mmHg) and Goldmann applanation tonometry (12.01 +/- 1.55 mmHg) IOP measurements were similar. Postoperative IOP was 10.30 +/- 1.16 mmHg with Goldmann applanation tonometry and 12.20 +/- 1.62 mmHg with pressure phosphene tonometry. The postoperative IOP difference between Goldmann applanation tonometry and pressure phosphene tonometry was 0.15 +/- 1.12 mmHg (P = .41). The mean change in pachymetry after LASIK was 68.73 +/- 73 microm. The change in Goldmann applanation between preoperative and postoperative LASIK values was 1.71 +/- 1.43 mmHg (P < .0001), a change that was strongly correlated with changes in corneal thickness (R = 0.75, P < .0001) and keratometry (R = 0.72, P < .0001). No such correlations were found with pressure phosphene tonometry. CONCLUSIONS Goldmann applanation tonometry-measured IOP decrease after LASIK is strongly correlated with a decrease in central corneal thickness and changes in keratometry, whereas pressure phosphene tonometry-measured IOP is independent of corneal thickness. Pressure phosphene tonometry appears to be a more reliable method for recording tonometry in these patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of different intraocular pressure measurement techniques in normal eyes, post surface and post lamellar refractive surgery

BACKGROUND The purpose of this study was to determine the accuracy of intraocular pressure (IOP) measurement after laser in situ keratomileusis (LASIK) or epithelial laser in situ keratomileusis (Epi)-LASIK using Goldmann applanation tonometry, air puff tonometry, ocular response analyzer corneal compensated IOP (ORA IOPcc) and Pentacam corrected IOP. METHODS A prospective comparative clinica...

متن کامل

Clinical evaluation of the pressure phosphene tonometer in patients with glaucoma.

AIM To evaluate the reliability of the pressure phosphene tonometer in comparison with the Goldmann applanation tonometer. METHODS 45 consecutive patients with glaucoma (78 eyes) participated in the study. Eyes with previous eye surgery, a documented peripheral visual field defect, a refractive error of more than 5 dioptres, and patients who were unable to understand the procedure were exclud...

متن کامل

Intraocular pressure and ocular rigidity after LASIK.

PURPOSE To assess the intraocular pressure (IOP) and ocular rigidity (E) at 1, 3, 6 and 24 postoperative months in eyes that underwent LASIK. METHODS The IOP measured by Goldmann applanation tonometer (GAT) and by the 5.5 and 10 gm. weights of a standardized Schioetz tonometer (ST) and the E measured by differential tonometry (the 5.5 and 10 gm. of ST) were assessed before and after LASIK (at...

متن کامل

Comparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients.

BACKGROUND To compare the intraocular pressure readings obtained with the iCare rebound tonometer and the 7CR non-contact tonometer with those measured by Goldmann applanation tonometry in treated glaucoma patients. DESIGN A prospective, cross-sectional study was conducted in a private tertiary glaucoma clinic. PARTICIPANTS OR SAMPLES One hundred nine (54 males : 55 females) patients includ...

متن کامل

Applanation tonometry: a comparison of the Perkins handheld and Goldmann slit lamp-mounted methods

PURPOSE To compare intraocular pressure (IOP) measurements, taken using Perkins applanation tonometry (PAT) and Goldmann applanation tonometry (GAT). METHODS 100 eyes of 100 patients underwent Perkins and Goldmann applanation tonometry, with a randomized order of modality, performed by a masked observer. The right eye was measured, for all subjects, and the data used in statistical analysis. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of refractive surgery

دوره 23 4  شماره 

صفحات  -

تاریخ انتشار 2007