Effects of a drill diameter on the temperature rise in a bone during implant site preparation under clinical conditions.

نویسندگان

  • Valerija Bogovič
  • Andrej Svete
  • Ivan Bajsić
چکیده

Heat, generated during the drilling of a dental implant site preparation, leads to a temperature rise and consequently to a thermal injury of the bone tissue surrounding the implant site, which can cause the subsequent implant failure. In this article, we present new findings related to the temperature rise during implant site drilling under real conditions on a bovine rib bone specimen. The experiments were designed with the help of a full-factorial design in randomized complete blocks, where the main effects of the drill diameter in combination with the drilling force and the drilling speed, and their interactions, on the temperature rise were determined. The temperature rise in the bone under real conditions was measured as the implant site was being prepared by a dentist using intermittent, graduated drilling and external irrigation. Results show that the drill diameter has statistically significant effect, independent of the drilling procedure used. Among the examined drilling parameters, the drill diameter has the greatest effect, where an increase in the drill diameter first causes a decrease in the temperature rise and further increase in the drill diameter causes its increase. During the continuous and one-step drilling, the temperatures of the bones were up to 40.5 °C and during the drilling under actual conditions up to 30.11 °C.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Implant Site Preparation by Piezoelectric and Conventional Drilling on Autograft Cell Viability: A Clinical Trial

Background and Aim: Implant site preparation with minimal trauma is an important factor in success of implant treatment and has a great effect on osseointegration. Piezoelectric bone surgery was introduced as a modern technique for micrometric osteotomy with precise, controllable action. Preservation of osteoblast cell viability is critical to achieve successful osseointegration. The present st...

متن کامل

Thermal changes and drill wear in bovine bone during implant site preparation. A comparative in vitro study: twisted stainless steel and ceramic drills.

OBJECTIVES The purpose was to assess thermal changes and drill wear in bovine bone tissue with the use of twisted stainless steel and zirconia-based drills, during implant site preparation. METHODS A total of 100 implant site preparations were performed on bovine ribs using a surgical unit linked to a testing device, in order to standardize/simulate implant drilling procedures. Bone temperatu...

متن کامل

A Comparison of Heat Generation in Different Depths of Implant Drilling Site with and without a Sleeve

Introduction: The purpose of this study was to compare the heat generated from different depths of an implant drilling site with and without a sleeve. Materials and methods: In this study, 60 cortical bone samples were used and a load of 2.0 kg was applied. rilling for implant surgery, we used a diameter of 4.3 mm and a normal sleeve. Heat was measured from 3 different depths(3,6, an...

متن کامل

ارزیابی تحلیل حرارتی عددی سوراخکاری استخوان فک در جراحی مرتبط با کاشت ایمپلنت

Background and Aims: Optimization drilling parameters in order to temperature decrease during creation of hole in the bone is an interested issue. The aim of this study was to achieve optimum values of drilling parameters based on the creation of minimum temperature during jawbone drilling. Materials and Methods: In this study two models of mandible and maxilla was created and teeth 2, 5...

متن کامل

Effect of surgical drill guide and irrigans temperature on thermal bone changes during drilling implant sites - thermographic analysis on bovine ribs.

Background/Aim During drilling implant sites, mechanical energy is converted into thermal one resulting in transient rise in temperature of surrounding bone. The temperature of 47°C exeeding one minute impairs osseointegration, compromises mechanical properties of the local bone and could cause early implant failure. This in vitro study aimed to assess the effect of surgical drill guide and tem...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine

دوره 230 10  شماره 

صفحات  -

تاریخ انتشار 2016