Lower cardiac troponin T and I results in heparin-plasma than in serum.

نویسندگان

  • H Stiegler
  • Y Fischer
  • J F Vazquez-Jimenez
  • J Graf
  • K Filzmaier
  • B Fausten
  • U Janssens
  • A M Gressner
  • D Kunz
چکیده

BACKGROUND The use of plasma rather than serum for determination of cardiac troponins can improve turnaround time and potentially avoid incomplete serum separation that may produce falsely increased results. We investigated the influence of incomplete serum separation and the effect of heparin-plasma on cardiac troponin concentrations. METHODS Serum and heparin-plasma samples were drawn simultaneously from 100 patients (50 patients with acute coronary syndrome and 50 patients after open heart surgery) and measured on three different analytical systems, two for determination of cardiac troponin I (cTnI; Abbott AxSYM and Bayer ACS:Centaur) and one for cardiac troponin T (cTnT; Roche Elecsys cTnT STAT). Serum samples were reanalyzed after a second centrifugation to assess the influence of incomplete serum separation. RESULTS Mean results (+/- 95% confidence interval) in heparin-plasma compared with serum were 101% +/- 2% (AxSYM cTnI), 94% +/- 3% (ACS:Centaur cTnI), and 99% +/- 3% (Elecsys cTnT). Differences >20% were seen in 11% of results on the ACS:Centaur, 9% of results on Elecsys cTnT, and 2% of results on the AxSYM. For the Elecsys cTnT assay, the magnitude of the difference between serum and plasma was independent of the absolute concentration and confined to individual samples, and was reversed by treatment with heparinase. A second centrifugation had no effect on serum results by any of the assays. CONCLUSION The concentrations of troponins measured in heparin-plasma are markedly lower than in serum in some cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Troponin T and I assays show decreased concentrations in heparin plasma compared with serum: lower recoveries in early than in late phases of myocardial injury.

BACKGROUND Heparinized plasma samples allow more rapid analysis than serum samples, but preliminary studies showed lower cardiac troponin T (cTnT) results in plasma. We undertook a multicenter study to characterize this effect for cTnT and cardiac troponin I (cTnI). METHODS Blood samples were collected with and without heparin at five hospitals. cTnT was measured by a "third generation" assay...

متن کامل

Evaluation of Troponin-T level in Neonate with Mechanical Ventilation

Introduction: Troponin- T is the best biological marker of heart injuries, that isn’t affected by sex, age, birth weight and gestational age. Myocardial damage in infancy is a risk factor eventual cardiac disease. This study carried out for cardiac evaluation of neonates with mechanical ventilation by Troponin T. Methods: This case-control study carried out on 60 infants that were admitte...

متن کامل

Correlation between the Level of Creatinine, Serum Cardiac Troponines and Left Ventricle Function Tests in Patients with Chronic Renal Diseases without Acute Coronary Syndrome

Background and Objectives:  The aim of this study was to survey the relationship between the level of  creatinine,cardiac troponins serum and the function of  the left ventricle in patients with  kidney insufficiency,without acute coronary syndrome. Materialsand Methods:The sample  was150 patients with nondialysis chronic kidney disease without  acute  coronary  syndrome,  hospitalized  at  I...

متن کامل

Evaluation of cardiac troponin I (cTnI), electrocardiography, creatine kinase (CK) and aspartate aminotransferase (AST) in diagnosis of selenium deficiency in Markhoz goat kids breed

BACKGROUND: Cardiac Troponin I (cTnI) is known as a cardiac biomarker in determining the myocardial damage of diseases which affect the heart muscle. OBJECTIVES: This study aims to evaluate the serum cTnI concentration in Markhoz Breed goats suffering selenium (Se) deficiency and its correlation with electrocardiographic parameters, and activity of creatine kinase (CK) and aspartate aminotransf...

متن کامل

Multicenter evaluation of an automated assay for troponin I.

BACKGROUND Cardiac troponin I (cTnI) is a powerful tool to aid in the diagnosis of myocardial infarction and cardiac muscle damage. We describe an assay that overcomes problems of early assays that were often affected by cTnI degradation, assay interference, poor sensitivity, and imprecision. METHODS The analytical performance of the Access AccuTnI assay (Beckman Coulter) was evaluated at fiv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 46 9  شماره 

صفحات  -

تاریخ انتشار 2000