Accurate and Efficient Mapping of Flip Angle and T1 using Simultaneous Actual Flip Angle - Variable Flip Angle Imaging (AFI-T1)
نویسندگان
چکیده
Introduction: The knowledge of flip angle values is essential for accurate modeling in many quantitative MRI techniques. Recently, Actual Flip Angle Imaging (AFI) was proposed to account for multiple sources of flip angle variations such as transmit field inhomogeneity, B0 variations, slab profile, and excitation pulse effects [1]. AFI was successfully applied to yield system-independent T1 relaxivity maps from variable flip angle (VFA) SPGR measurements [1-4]. AFI assumes the repetition time is much less than T1. When this assumption is violated, significant errors in flip angle and in subsequent T1 estimates may arise.
منابع مشابه
Improved T1 mapping with Iterative Actual Flip-angle Imaging (iAFI) Technique
Introduction: Accurate measurement of T1 is essential for many quantitative MRI techniques, such as dynamic contrast enhanced MRI. Variable flip angle (VFA) spoiled gradient echo imaging is one of the most widely used methods for T1 mapping [1]. However, this technique often suffers from flip angle inaccuracies due to inhomogeneous RF fields and slice profile effects [2]. Actual flip-angle imag...
متن کاملSpoiling properties of the VAFI method for fast simultaneous T1 and B1 mapping from actual flip-angle imaging (AFI) and variable flip-angle (VFA) data
ntroduction: Accurate measurements of both T1 and flip angle (FA) are important to many quantitative imaging applications. The use of steady-state sequences offers a fast way to acquire 3D volumetric maps of these parameters, and the recently proposed combined fitting of variable flip angle (VFA) [1] and actual flip-angle imaging (AFI) [2] data (VAFI) has been shown to be highly accurate and ef...
متن کاملبهینه سازی نگاره های MRA مغز با استفاده از ماده کنتر است زا در میدان مغناطیسی 1.5 تسلا
Background and purpose: Selection of suitable parameters for brain MRA requires accurate measures, because the image quality depends on the location of arteries, veins and also the velocity differences of blood, taking into account the low blood flow in small veins and arteries, use of paramagnetic contrast media is recommended. Hence, in present study, we investigated the imaging optimizatio...
متن کاملTransmit B1+ field inhomogeneity and T1 estimation errors in breast DCE-MRI at 3 tesla.
PURPOSE To quantify B1+ variation across the breasts and to evaluate the accuracy of precontrast T1 estimation with and without B1+ variation in breast MRI patients at 3 Tesla (T). MATERIALS AND METHODS B1+ and variable flip angle (VFA) T1 mapping were included in our dynamic contrast-enhanced (DCE) breast imaging protocol to study a total of 25 patients on a 3.0T GE MR 750 system. We compute...
متن کاملFlip-angle-optimized fast dynamic T1 mapping
Purpose: To analyze the flip-angle dependence and to optimize the statistical precision of a fast three-dimensional T1-mapping technique based on the variable-flip-angle (VFA) method. The proposed single-flip-angle (1FA) approach acquires only a single 3D spoiled gradient-echo data set for each time point of the dynamical series in combination with a longer baseline measurement. Theory and Meth...
متن کامل