Optimal detailed design for integral cooling water systems

نویسندگان

  • José M. Ponce-Ortega
  • Medardo Serna-González
  • Arturo Jiménez-Gutiérrez
  • Nicolás de Hidalgo
چکیده

A cooling water system is used in industrial processes to cool down hot process streams from their supply conditions to target temperatures. A cooling water system is comprised of three major components, namely a cooling tower, a heat exchanger network (HEN), and a pumping system; these elements have strong interactions with each other and therefore must be optimized simultaneously to yield an optimal cooling water system. This paper presents a mixed-integer non linear programming model for the optimal design of integral cooling water systems. The model includes a superstructure for the HEN component of the system that allows arrangements of coolers in series and/or in parallel, and also allows the bypass of fresh water and/or previously-used water to improve the performance of the cooling network. The optimization of HEN coolers is made simultaneously to take into consideration from the synthesis stage the interactions between the pumping effects and the heat transfer coefficients that determine their transfer areas. The model considers as objective function the minimization of the capital costs for the cooling tower, HEN coolers and pumps, as well as the operating costs due to the fan of the tower, pumping requirements and water makeup. One example problem is presented to show the application of the proposed method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal Design of Cooling Water Systems

Re-circulating cooling water systems are generally used to remove waste heat from hot process streams in conditions above the ambient temperature in many types of industries such as chemical and petrochemical, electric power generating stations, refrigeration and air conditioning plants, pulp and paper mills, and steel mills. Typical re-circulating cooling water systems are constituted by a mec...

متن کامل

Self-optimizing Control of Cooling Tower for Efficient Operation of Chilled Water Systems

The chilled-water systems, mainly consisting of electric chillers and cooling towers, are crucial for the ventilating and air conditioning systems in commercial buildings. Energy efficient operation of such systems is thus important for the energy saving of commercial buildings. This paper presents an extremum seeking control (ESC) scheme for energy efficient operation of the chilled-water syst...

متن کامل

Optimal Short-Term Scheduling of Multi-Chiller Plants Considering Energy Requirement of Cooling Towers, Pumps and Chillers

During extremely hot summer days, air conditioning systems are known as major electricity consumers in residential, commercial and industrial sectors. Moreover, high energy requirement of multiple-chiller plants may cause an interconnected power grid be faced with annual on-peak electrical demand, load-generation mismatch, voltage collapse and catastrophic wide area blackout. Therefore, this pa...

متن کامل

Integrated Chiller System Reduce Building Operation and Maintenance Costs in Cold Climates

Although water-cooled chillers are more energy efficient than air-cooled chillers, a majority of chilled water systems use air-cooled chillers. In cold weather climates, air-cooled chillers are capable of functioning in low ambient temperatures with few operational concerns, where as water-cooled chiller systems must be equipped to prevent cooling tower freezing. The integrated chiller system a...

متن کامل

An Improved Modular Modeling for Analysis of Closed-Cycle Absorption Cooling Systems

A detailed modular modeling of an absorbent cooling system is presented in this paper. The model including the key components is described in terms of design parameters, inputs, control variables, and outputs. The model is used to simulate the operating conditions for estimating the behavior of individual components and system performance, and to conduct a sensitivity analysis based on the give...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008