Aperture tolerances for neutron-imaging systems in inertial confinement fusion.

نویسندگان

  • M C Ghilea
  • T C Sangster
  • D D Meyerhofer
  • R A Lerche
  • L Disdier
چکیده

Neutron-imaging systems are being considered as an ignition diagnostic for the National Ignition Facility (NIF) [Hogan et al., Nucl. Fusion 41, 567 (2001)]. Given the importance of these systems, a neutron-imaging design tool is being used to quantify the effects of aperture fabrication and alignment tolerances on reconstructed neutron images for inertial confinement fusion. The simulations indicate that alignment tolerances of more than 1 mrad would introduce measurable features in a reconstructed image for both pinholes and penumbral aperture systems. These simulations further show that penumbral apertures are several times less sensitive to fabrication errors than pinhole apertures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Neutron Imaging with Bubble Chambers for Inertial Confinement Fusion

One of the main methods to obtain energy from controlled thermonuclear fusion is inertial confinement fusion (ICF), a process where nuclear fusion reactions are initiated by heating and compressing a fuel target, typically in the form of a pellet that contains deuterium and tritium, relying on the inertia of the fuel mass to provide confinement. In inertial confinement fusion experiments, it is...

متن کامل

A measurable Lawson criterion and hydro-equivalent curves for inertial confinement fusion

Related Articles Recover soft x-ray spectrum using virtual flat response channels with filtered x-ray diode array Rev. Sci. Instrum. 83, 113102 (2012) Average atom transport properties for pure and mixed species in the hot and warm dense matter regimes Phys. Plasmas 19, 102709 (2012) A novel technique for single-shot energy-resolved 2D x-ray imaging of plasmas relevant for the inertial confinem...

متن کامل

Inverse Braking Radiation and Resonance Absorption in Corona Plasmas of Inertial Confinement Fusion

Abstract: In this paper, combining the Maxwell equations with the electron balanceequation, we obtain the inverse braking radiation absorption coefficient in a laser fusioncorona plasma. For a fixed plasma temperature, variations of the absorption coefficientversus the penetration depth into the plasma are illustrated numerically for differentvalues of laser wavelength. ...

متن کامل

Optical properties and structure of Pr3+-doped Al(PO3)3–LiF glasses as scattered neutron scintillator for nuclear fusion diagnostics

Scattered neutron diagnostics is an indispensable tool for both inertial confinement and magnetic confinement fusion research. For this purpose, a fast-response neutron scintillator with a high cross section for scattered neutrons is strongly required. Recently, based on our material design strategy, we have successfully developed the fast response time Pr-doped 20Al(PO3)3–80LiF glass scintilla...

متن کامل

UWFDM-1394 Structural Materials Damage in Fusion and Fission Systems

Calculations were performed to quantify the damage parameters in the leading candidate structural and plasma facing materials when used in magnetic and inertial confinement fusion systems and when irradiated in fission reactors. The structural materials considered are ferritic steel, austenitic steel, vanadium alloy and SiC/SiC composite. Plasma facing materials included beryllium, tungsten, an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 79 2 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2008