Role of visual field reliability indices in ruling out glaucoma.

نویسندگان

  • Harsha L Rao
  • Ravi K Yadav
  • Viquar U Begum
  • Uday K Addepalli
  • Nikhil S Choudhari
  • Sirisha Senthil
  • Chandra S Garudadri
چکیده

IMPORTANCE Standard automated perimetry is the current criterion standard for assessment of visual field (VF) loss in glaucoma. The 3 commonly used reliability indices to judge the quality of standard automated perimetry results are fixation losses (FLs) and false-positive (FP) and false-negative (FN) response rates. However, the influence of reliability indices, when within the manufacturer-recommended limits, on VF classification has been sparsely studied. OBJECTIVE To evaluate the role of VF reliability indices in ruling out glaucoma. DESIGN, SETTING, AND PARTICIPANTS A cross-sectional study of 291 eyes of 291 participants referred to a tertiary eye care facility by general ophthalmologists. The participants were suspected to have glaucoma based on optic disc appearance, but the eyes were judged to be normal with physiological cupping by glaucoma experts on masked evaluation of optic disc photographs. All participants underwent VF testing with the Swedish interactive threshold algorithm standard 24-2 program. MAIN OUTCOMES AND MEASURES Logistic regression models were used to evaluate the associations between reliability indices and FP classifications on VF testing (glaucoma hemifield test as outside normal limits and pattern standard deviation with P < .05). RESULTS Median FL, FP, and FN response rates were 7%, 1%, and 2%, respectively. Among the 241 participants with reliable VF results (FL <20% and FP response rate <15%), the VF classification was normal in 188 (78.0%) and glaucoma (FP) in 53 (22.0%). Probability of FP VF classification was associated with FN response rates (odds ratio [OR], 1.36; 95% CI, 1.25-1.48, P < .001) but did not appear to be associated with FLs (OR, 0.96; 95% CI, 0.90-1.03, P = .30) or FP response rates (OR, 0.96; 95% CI, 0.83-1.12, P = .64). Predicted probability of FP VF classification was 9% (95% CI, 6%-14%), 40% (32%-49%), and 82% (68%-91%) at FN response rates of 0%, 8%, and 16%, respectively. CONCLUSIONS AND RELEVANCE This study suggests that FN response rates have an effect on the ability of automated VF assessments to rule out glaucoma. Since FN response rates are ignored by the manufacturer while flagging a test as unreliable, clinicians and researchers may benefit by realizing that FN response rates can lead to FP VF classification, even when their frequencies are small.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the effects of glaucomatous (POAG) damage on the mVEP parameters

Introduction: Glaucoma is considered as a major cause of irreversible vision loss, worldwide. Glaucoma includes a diverse ophthalmopathies characterized by attenuating the neural and connective tissue segments and eventually progression of specific patterns of visual dysfunction. Currently, perimetry is known as the most accurate diagnostic method in glaucoma and its follow up...

متن کامل

Four-dot Artifact on Automated Perimetry

A 74-year-old woman was referred to the glaucoma unit for pseudoexfoliative glaucoma. Upon presentation, visual acuity in both eyes was 20/30. Intraocular pressure was 18 mmHg in the right eye and 20 mmHg in the left eye with latanoprost eye drops. Ophthalmoscopy revealed a cup-disc ratio of 0.7 with superior neural rim notching in the right eye and concentric cup-disc ratio of 0.6 in the left ...

متن کامل

Misleading statistical calculations in far-advanced glaucomatous visual field loss.

OBJECTIVE In this study, the capability of statistical analysis indices to characterize static automated visual fields (VFs) accurately in cases of far-advanced glaucoma was assessed. DESIGN Retrospective observational case series. PARTICIPANTS Sixteen eyes of 15 patients with end-stage glaucoma and evidence of collapse of VF statistical analysis indices were included in the study. METHOD...

متن کامل

[Automated perimetry in patients with primary congenital glaucoma].

PURPOSE To identify and characterize defects using the automated perimetry test in patients with primary congenital glaucoma. METHODS Automated visual fields and charts of 81 eyes (48 patients) with congenital glaucoma were retrospectively analyzed, 15 being normal eyes (group N) and 66 eyes with primary congenital glaucoma (group G). Eyes of group G were grouped in eyes without perimetric ch...

متن کامل

Quantification of glaucomatous visual field defects with automated perimetry.

A method to quantify different glaucomatous visual field defects is presented. Three visual field indices are calculated: the short-term fluctuation, the mean defect, and the corrected loss variation. The method was applied to visual fields tested with program JO on the Octopus automated perimeter. The indices of 130 glaucoma suspects and 50 glaucoma patients were compared with 100 normal contr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JAMA ophthalmology

دوره 133 1  شماره 

صفحات  -

تاریخ انتشار 2015